Out of stock
- Sensor head bidirectional and rotatable
- NO/NC selectable
- Comfort series
The inductive proximity sensors from Pepperl+Fuchs are designed for reliable non-contact detection of metallic objects in various industrial applications. These sensors operate on the principle of electromagnetic induction, offering high accuracy and fast response times, making them suitable for automation processes where precision is critical.
Common applications include detecting the position of moving parts in machinery, monitoring material presence on conveyor systems, and controlling automated assembly lines. The sensors feature a bidirectional and rotatable sensor head, allowing for flexible installation and orientation to meet specific application needs. Additionally, the selectable normally open (NO) and normally closed (NC) configurations enhance their adaptability for different control systems.
| Operating voltage indicator | LED, green |
| Degree of protection | IP67 |
| Hysteresis | 1 … 10 typ. 5 % |
| Reverse polarity protection | reverse polarity tolerant |
| Assured operating distance | 0 … 32.4 mm |
| CCC approval | Ue 75VDC – 250VDC Ue 75VAC – 230VAC |
| Output type | Two-wire |
| Rated operating distance | 40 mm |
| Housing base | plastic |
| Output type | 2-wire |
| Installation | non-flush |
| Switching state indicator | LED, yellow |
| Voltage drop | 5 V (typ. 2V) DC operation 8 V (typ. 2V) AC operation |
| Connection type | terminal compartment |
| Switching function | Normally open/closed (NO/NC) |
| Momentary current (20 ms, 0.1 Hz) |
0 … 3000 mA |
| UL approval | cULus Listed, General Purpose “”For use in NFPA 79 Applications only”” For overcurrent protection, install a fuse with a rated current of max. 3 A and at least 300 V AC/DC |
| Operating voltage | 20 … 300 V DC / 20 … 253 V AC |
| Reduction factor rAl | 0.37 |
| Short-circuit protection | pulsing |
| Reduction factor rBrass | 0.4 |
| Operating current | 5 … 500 mA |
| Ambient temperature | -25 … 85 °C (-13 … 185 °F) |
| Housing material | PA 6.6 / metal |
| Switching frequency | 0 … 25 Hz |
| Time delay before availability | 300 ms |
| Storage temperature | -25 … 85 °C (-13 … 185 °F) |
| Error indicator | flashes when overcurrent |
| Rated operating voltage | 24 … 250 V DC / 24 … 230 V AC |
| Protection class | II |
| Core cross-section | up to 2.5 mm2 |
| Reduction factor rCu | 0.3 |
| Output polarity | AC/DC |
| Reduction factor rFe | 1 |
| Off-state current | 1.5 mA |
| Information for connection | A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 % |
| Actual operating distance | 36 … 44 mm typ. 40 mm |
| Sensing face | PA 6.6 |
| Reduction factor r304 | 0.73 |
Currently, the goods have no revocation.
Your feedback will be the first to
Share your thoughts, your opinion about the product.
Thank you for your feedback. In order to leave your feedback, simply fill out the form below.