The I/O hub features a robust metallic housing and offers an IO-link interface for efficient service and process data management. With 16 configurable digital inputs and outputs, this hub allows for precise control and monitoring in industrial applications.
The I/O hub is designed for flexible integration in industrial automation environments, facilitating communication between sensors, actuators, and control systems. Its 16 digital inputs and outputs can be configured independently, enabling users to tailor settings such as logic levels, filter times, and pulse extensions to meet specific operational requirements.
Common applications of the I/O hub include machine control, process automation, and data acquisition in manufacturing settings. The ability to configure each port enhances the adaptability of the system, allowing for optimal performance in diverse scenarios. By utilizing the IO-link interface, users can seamlessly manage service and process data, ensuring efficient monitoring and control of connected devices.
| IO-Link Revision | 1.1 |
| Storage temperature | -40 … 70 °C (-40 … 158 °F) |
| Connection | Power supply/IO-Link M12, A-coded Inputs/Outputs M12, A-coded |
| Current consumption | typ. 80 mA |
| Rated operating voltage | 18 … 30 V |
| Vibration resistance | 15 g / 5 … 500 Hz |
| Degree of protection | EN 60529:2000 |
| Mass | 400 g |
| LED UAUX | Green: Actuator supply voltage OK Red: Actuator supply voltage < 18 V |
| Emitted interference | EN 61000-6-2:2005 |
| LED B | White: status indicator channel B Red: peripheral error |
| Pollution degree | 3 |
| Process data width | Input 4 Byte Output 4 Byte |
| Compatible master port type | A |
| LED US | Green: system/sensor supply voltage OK Red: system/sensor supply voltage < 18 V Flashing red: sensor supply voltage overload |
| Device profile | Identification and Diagnosis |
| Sensor supply | max. 500 mA Per port (X1 – X8) |
| UL File Number | E223772 |
| Degree of protection | IP65/IP67/IP69K |
| Noise immunity | EN 61000-6-4:2007+A1:2011 |
| Nominal voltage | 24 V DC |
| Construction type | Field housing |
| Min. cycle time | 2 ms |
| LED IO-Link | Green: module is switched on, no communication Flashing green: communication OK Red: signal line overload |
| Output rated operating current | max. 2 A per channel (X1 – X8) / 4 A Per port max. 9 A per module |
| Number/Type | 16 digital inputs/outputs, configurable Inputs: 2-, 3-, 4-wire PNP, DC, supply from US Outputs: 2-wire PNP, DC, supply from UL No galvanic isolation between US and UL short-circuit protected |
| Fieldbus standard | Type 1 according to IEC 61131-2 |
| Transfer rate | COM 3 (230.4 kBaud) |
| Relative humidity | max. 95 % |
| Nominal current | 16 A |
| Device ID | 0x0F0203 (983555) |
| Interface type | IO-Link |
| MTTFd | 2111 a |
| SIO mode support | no |
| Current loading capacity | max. 16 A per module (for UL applications, max. 9 A) |
| Shock and impact resistance | 50 g, 11 ms, all axes |
| Altitude | 0 … 2000 m |
| LED A | Orange: status indicator channel A Red: peripheral error |
| Ambient temperature | -20 … 70 °C (-4 … 158 °F) |
Currently, the goods have no revocation.
Your feedback will be the first to
Share your thoughts, your opinion about the product.
Thank you for your feedback. In order to leave your feedback, simply fill out the form below.