The SMART Transmitter Power Supply/SMART Current Driver is designed as a 2-channel isolated barrier, providing a reliable 24 V DC supply through a Power Rail. It supports both analog input (AI) and analog output (AO) functionalities, making it versatile for various industrial applications.

All description
Manufacturer: Pepperl+Fuchs
Description:

The Pepperl+Fuchs SMART Transmitter Power Supply/SMART Current Driver serves as a crucial component in industrial automation systems, particularly in hazardous environments where intrinsic safety is paramount. This product family is engineered to provide isolated power and signal processing for smart transmitters and various analog devices, ensuring accurate data transmission and robust system performance.

Common applications include process control and monitoring in industries such as oil and gas, chemical processing, and pharmaceuticals. The device operates effectively as either a transmitter power supply or a current driver, accommodating diverse requirements in the field. With a compact housing width of just 12.5 mm, it facilitates easy integration into existing control systems while meeting safety standards up to SIL 2 (SC 3) according to IEC/EN 61508.

Signal type Analog input/analog output
Safety Integrity Level (SIL) SIL 2
Systematic capability (SC) SC 3
Connection Power Rail or terminals 9+, 10-
Rated voltage 19 … 30 V DC
Ripple max. 10 %
Rated current max. 88 mA at 24 V
Power dissipation max. 1.4 W
Power consumption max. 2.1 W
Number of channels 2
Suitable field devices 2-wire SMART transmitters
Signal 0/4 … 20 mA , limited to approx. 30 mA
Field circuit terminals 1+, 2-, 3+, 4-
Available voltage min. 15 V at 20 mA
min. 18 V at 4 mA
Control circuit terminals 5-, 6+; 7-, 8+
limited electrical values : max. 30 V , max. 2 A
Input voltage Voltage across terminals 10 … 30 V. If the current is supplied from a source > 24 V,
series resistance of ‰§ (V – 24)/0.02 Ω is needed, where V is the source voltage.
The maximum value of the resistance is (V – 10)/0.02 Ω. (sink output)
Load max. 350 Ω (source output)
Ripple 20 mV eff
Number of channels 2
Suitable field devices SMART I/P converters (positioner), on-site-displays
Signal 0/4 … 20 mA , limited to approx. 30 mA
Field circuit terminals 1+, 2-, 3+, 4-
Load max. 650 Ω
Voltage min. 13 V at 20 mA
Ripple 20 mV eff , on all signal terminals
Control circuit terminals 5-, 6+; 7-, 8+
limited electrical values : max. 30 V , max. 2 A
Voltage drop max. 6 V
Line fault detection > 100 kΩ at max. 30 V, with field wiring open
Deviation max. 20 µA incl. calibration, linearity, hysteresis, loads and fluctuations of supply voltage
Influence of ambient temperature < 2 µA/K (-40 … 70 °C (-40 … 158 °F))
Frequency range field side into the control side: bandwidth with 0.5 Vpp signal 0 … 3 kHz (-3 dB)
control side into the field side: bandwidth with 0.5 Vpp signal 0 … 3 kHz (-3 dB)
Settling time max. 200 ms
Rise time/fall time max. 100 ms (10 … 90 %)
Field circuit/control circuit basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Control circuit/control circuit functional isolation, rated voltage: 50 V
Field circuit/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Control/power supply basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Display elements LED
Factory setting analog input with source output
Configuration via DIP switches
Labeling space for labeling at the front
Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Electromagnetic compatibility NE 21:2017
EN 61326-3-2:2018
Degree of protection IEC 60529:2001
Protection against electrical shock UL 61010-1:2019
Ambient temperature -40 … 70 °C (-40 … 158 °F)
Degree of protection IP20
Connection screw terminals
Mass approx. 115 g
Dimensions 12.5 x 124 x 114 mm (0.5 x 4.9 x 4.5 inch) (W x H x D) , housing type A2
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
EU-type examination certificate UL 22 ATEX 2786 X
Marking II (1)G [Ex ia Ga] IIC
II (1)D [Ex ia Da] IIIC
I (M1) [Ex ia Ma] I
Output Ex ia, Ex iaD
Voltage 25.2 V
Current 100 mA
Power 630 mW
Internal capacitance 1.05 nF
Internal inductance 0
Supply
Maximum safe voltage 250 V rms (Attention! The rated voltage can be lower.)
Input
Maximum safe voltage 250 V rms (Attention! The rated voltage can be lower.)
Certificate UL 22 ATEX 2787 X
Marking II 3G Ex ec IIC T4 Gc [device in zone 2]
Galvanic isolation
Field circuit/control circuit safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Field circuit/power supply safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity
Directive 2014/34/EU EN IEC 60079-0:2018 , EN 60079-11:2012 , EN IEC 60079-7:2015+A1:2018
UL approval E106378
Control drawing 116-0490 (cULus)
IECEx approval
IECEx certificate IECEx ULD 22.0020X
IECEx marking [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I
Ex ec IIC T4 Gc
Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
ECLASS 13.0 27210120
ECLASS 12.0 27210120
ECLASS 11.0 27210120
ECLASS 10.0.1 27210120
ECLASS 9.0 27210120
ECLASS 8.0 27210120
ECLASS 5.1 27210120
ETIM 9.0 EC002653
ETIM 8.0 EC002653
ETIM 7.0 EC002653
ETIM 6.0 EC002653
ETIM 5.0 EC001485
UNSPSC 12.1 32101514
Reviews
Leave feedback on the goods

Currently, the goods have no revocation.
Your feedback will be the first to
Share your thoughts, your opinion about the product.

Leave feedback

Thank you for your feedback. In order to leave your feedback, simply fill out the form below.

Thank you for your feedback. In order to leave your feedback, simply fill out the form below. “Pepperl+Fuchs KCD2-SCS-Ex2”

Your email address will not be published. Required fields are marked *

Other products categories