Interface for Power Rail
-
Used for redundant configuration
The Redundant Power Feed Module is designed to enhance the reliability of power distribution in intrinsically safe systems. This module serves as a vital interface for power rails, facilitating redundant configurations that are essential for ensuring continuous operation in hazardous environments. By incorporating redundancy, this module minimizes the risk of system failure, thereby improving overall safety and operational efficiency.
Common applications for the Redundant Power Feed Module include process automation, petrochemical industries, and other environments where safety is paramount. Its robust design allows it to function effectively in conjunction with various intrinsic safety barriers, providing a reliable power solution that meets stringent safety standards. The module’s compatibility with existing systems makes it a versatile choice for engineers looking to implement reliable power solutions in demanding applications.
|
Degree of protection |
IEC 60529:2001 |
|
Labeling |
space for labeling at the front |
|
Output voltage |
24 V DC |
|
Fault signal |
relay output: NO contact |
|
Energized/De-energized delay |
approx. 20 ms / approx. 20 ms |
|
Fusing |
5 A recommended maximum utilization of the fuse: 80 % |
|
Connection |
Power Rail |
|
Connection |
screw terminals |
|
Electromagnetic compatibility |
NE 21:2006 |
|
Mounting |
on 35 mm DIN mounting rail acc. to EN 60715:2001 |
|
Rated voltage |
20 … 30 V DC The maximum rated operating voltage of the devices plugged onto the Power Rail must not be exceeded. |
|
Mass |
approx. 100 g |
|
Power dissipation |
2.4 W |
|
Contact loading |
30 V AC/ 2 A / cos andphi; 0.7 ; 40 V DC/ 2 A |
|
Ambient temperature |
-20 … 60 °C (-4 … 140 °F) |
|
IECEx approval |
IECEx UL 16.0051X |
|
Display elements |
LEDs |
|
Optional accessories |
– universal power rail UPR-03(-M)(-S) – universal power rail UPR-05(-S) – profile rail K-DUCT-GY(-UPR-03) – profile rail K-DUCT-GY(-UPR-05) – profile rail K-DUCT-BU(-UPR-03) – profile rail K-DUCT-BU(-UPR-05) |
|
Control elements |
DIP-switch |
|
Supplementary information |
Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
|
Output rated operating current |
max. 4 A |
|
Connection |
terminals 11+, 12- terminals 8+, 9- |
|
Dimensions |
20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2 |
|
Degree of protection |
IP20 |
|
Configuration |
via DIP switches |