Pepperl+Fuchs KFD2-HLC-Ex1.D

HART Loop Converter
SKU: KFD2-HLC-Ex1.D
0.00

Out of stock

One click request

The HART Loop Converter is a versatile 1-channel isolated barrier designed for HART field devices. It provides a reliable 24 V DC supply and is capable of functioning as a signal splitter with multiple outputs.

All description
Manufacturer: Pepperl+Fuchs
Description:

The HART Loop Converter belongs to a specialized family of intrinsic safety barriers that facilitate the safe integration of HART-enabled field devices into process control systems. These devices are specifically engineered for environments where safety and reliability are paramount, ensuring that signals are transmitted without compromising the integrity of the system.

This converter supports a 24 V DC power supply for the connected HART field device and is equipped with a transmitter power supply to enhance operational flexibility. It features three analog outputs, each capable of delivering a standard current signal in the range of 4 mA to 20 mA, allowing for seamless data communication across various system components. Configurable via a keypad, the device also supports both sink and source output modes, making it adaptable for diverse application needs.

Power dissipation 2.3 W
Mass 300 g
Configuration via operating buttons
via PACTware
Current range 4 … 20 mA , (source or sink mode)
Output I/II/III/power supply functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff
Connection Power Rail or terminals 23+, 24-
Optional accessories – power feed module KFD2-EB2(.R4A.B)(.SP)
– universal power rail UPR-03(-M)(-S)
– profile rail K-DUCT-BU(-UPR-03)
EU-Type Examination Certificate BASEEFA 07 ATEX 0174
Connection output I: terminals 7, 8, 9 , output II: terminals 13, 14, 15 , output III: terminals 19, 20, 21
Dimensions 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) , housing type C3
Signal type Analog input
Programming interface programming socket
Input resistance 250 andOmega; , 5 % (terminals 2, 3 and with jumper on 5, 6)
Connection terminals 1, 2, 3, 4, 5, 6
Degree of protection IEC 60529:2001
Output I, II, III terminals 7, 8, 9; 13, 14, 15; 19, 20, 21 non-intrinsically safe
Certificate PF 07 CERT 1142 X
Control elements Control panel
Other outputs HART communicator on terminals 22, 24
Equipment terminals 1, 4/3 (with link between terminals 4 and 5)
Rated voltage 19 … 30 V DC
Connection side control side
Power consumption 2.9 W
Fault signal downscale I 2 mA, upscale I 21.5 mA (acc. NAMUR NE43) or hold measurement value
Open circuit voltage/short-circuit current typ. 24 V / 28 mA
Display elements LEDs , display
Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Output signal analog
Conformity HART field device input (revision 5 to 7)
Available voltage 15.5 V at 20 mA, short-circuit protected
Degree of protection IP20
Labeling space for labeling at the front
Connection screw terminals
Electromagnetic compatibility NE 21:2006
Rated current approx. 120 mA at 24 V DC
Collective error message Power Rail and LED red
Equipment terminals 2, 5/3
Ambient temperature -20 … 60 °C (-4 … 140 °F)
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
Voltage range 5 … 30 V , sink mode from external supply
Load max. 650 andOmega; , source mode
Reviews
Leave feedback on the goods

Currently, the goods have no revocation.
Your feedback will be the first to
Share your thoughts, your opinion about the product.

Leave feedback

Thank you for your feedback. In order to leave your feedback, simply fill out the form below.

Thank you for your feedback. In order to leave your feedback, simply fill out the form below. “Pepperl+Fuchs KFD2-HLC-Ex1.D”

Your email address will not be published. Required fields are marked *

Other products categories