Out of stock
The HART Loop Converter is a versatile 1-channel isolated barrier designed for HART field devices. It provides a reliable 24 V DC supply and is capable of functioning as a signal splitter with multiple outputs.
The HART Loop Converter belongs to a specialized family of intrinsic safety barriers that facilitate the safe integration of HART-enabled field devices into process control systems. These devices are specifically engineered for environments where safety and reliability are paramount, ensuring that signals are transmitted without compromising the integrity of the system.
This converter supports a 24 V DC power supply for the connected HART field device and is equipped with a transmitter power supply to enhance operational flexibility. It features three analog outputs, each capable of delivering a standard current signal in the range of 4 mA to 20 mA, allowing for seamless data communication across various system components. Configurable via a keypad, the device also supports both sink and source output modes, making it adaptable for diverse application needs.
| Power dissipation | 2.3 W |
| Mass | 300 g |
| Configuration | via operating buttons via PACTware |
| Current range | 4 … 20 mA , (source or sink mode) |
| Output I/II/III/power supply | functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff |
| Connection | Power Rail or terminals 23+, 24- |
| Optional accessories | – power feed module KFD2-EB2(.R4A.B)(.SP) – universal power rail UPR-03(-M)(-S) – profile rail K-DUCT-BU(-UPR-03) |
| EU-Type Examination Certificate | BASEEFA 07 ATEX 0174 |
| Connection | output I: terminals 7, 8, 9 , output II: terminals 13, 14, 15 , output III: terminals 19, 20, 21 |
| Dimensions | 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) , housing type C3 |
| Signal type | Analog input |
| Programming interface | programming socket |
| Input resistance | 250 andOmega; , 5 % (terminals 2, 3 and with jumper on 5, 6) |
| Connection | terminals 1, 2, 3, 4, 5, 6 |
| Degree of protection | IEC 60529:2001 |
| Output I, II, III | terminals 7, 8, 9; 13, 14, 15; 19, 20, 21 non-intrinsically safe |
| Certificate | PF 07 CERT 1142 X |
| Control elements | Control panel |
| Other outputs | HART communicator on terminals 22, 24 |
| Equipment | terminals 1, 4/3 (with link between terminals 4 and 5) |
| Rated voltage | 19 … 30 V DC |
| Connection side | control side |
| Power consumption | 2.9 W |
| Fault signal | downscale I 2 mA, upscale I 21.5 mA (acc. NAMUR NE43) or hold measurement value |
| Open circuit voltage/short-circuit current | typ. 24 V / 28 mA |
| Display elements | LEDs , display |
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| Output signal | analog |
| Conformity | HART field device input (revision 5 to 7) |
| Available voltage | 15.5 V at 20 mA, short-circuit protected |
| Degree of protection | IP20 |
| Labeling | space for labeling at the front |
| Connection | screw terminals |
| Electromagnetic compatibility | NE 21:2006 |
| Rated current | approx. 120 mA at 24 V DC |
| Collective error message | Power Rail and LED red |
| Equipment | terminals 2, 5/3 |
| Ambient temperature | -20 … 60 °C (-4 … 140 °F) |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
| Voltage range | 5 … 30 V , sink mode from external supply |
| Load | max. 650 andOmega; , source mode |
Currently, the goods have no revocation.