Out of stock
The Switch Amplifier is a versatile 1-channel isolated barrier designed for use in hazardous environments. It supports a 24 V DC supply and is compatible with dry contact or NAMUR inputs.
The Switch Amplifier is part of the Pepperl+Fuchs portfolio of intrinsic safety barriers, specifically engineered to facilitate safe signal transmission in explosive atmospheres. This product provides essential isolation between field devices and control systems, ensuring that signals are transmitted without the risk of igniting flammable gases or dust. Its design incorporates a reliable isolated passive transistor output and an isolated passive fault output, both of which are non-polarized, allowing for seamless integration into a variety of applications.
Common applications of the Switch Amplifier include process automation, safety systems, and signal splitting tasks, where one input needs to be converted to multiple outputs. The device is equipped with line fault detection (LFD) capabilities, which enhance system reliability by identifying wiring faults. Additionally, the reversible mode of operation allows for flexible configuration to meet specific operational requirements, making it suitable for diverse industrial environments while adhering to safety standards up to SIL 2 according to IEC 61508.
| Switching frequency | ≤ 5 kHz |
| Line fault detection | breakage I ≤ 0.1 mA , short-circuit I > 6 mA |
| EU-type examination certificate | PTB 00 ATEX 2035 |
| Galvanic isolation | IEC 62103:2003 |
| Signal level | 1-signal: switching voltage – 2.5 V max. at 10 mA switching current or 3 V max. at 100 mA switching current 0-signal: switched off (off-state current ≤ 10 µA) |
| Input/Output | reinforced insulation acc. to IEC 62103, rated insulation voltage 300 Vrms |
| Safety Integrity Level (SIL) | SIL 2 |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
| Electromagnetic compatibility | NE 21:2004 |
| Degree of protection | IEC 60529:2001 |
| Switching current | max. 100 mA , short-circuit protected |
| Switching voltage | max. 30 V |
| Rated current | ≤ 50 mA |
| Display elements | LEDs |
| Labeling | space for labeling at the front |
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| Switching point/switching hysteresis | 1.2 … 2.1 mA / approx. 0.2 mA |
| Ripple | ≤ 10 % |
| Ambient temperature | -20 … 60 °C (-4 … 140 °F) |
| Connection | screw terminals |
| Degree of protection | IP20 |
| Output/power supply | basic insulation according to IEC 62103, rated insulation voltage 50 Veff |
| Rated values | acc. to EN 60947-5-6 (NAMUR), see manual for electrical data |
| Signal type | Digital Input |
| Collective error message | Power Rail |
| Control elements | DIP-switch |
| Input/power supply | reinforced insulation acc. to IEC 62103, rated insulation voltage 300 Vrms |
| Mass | approx. 150 g |
| Rated voltage | 20 … 30 V DC |
| IECEx approval | IECEx PTB 05.0011 |
| Connection | Power Rail or terminals 14+, 15- |
| Connection | terminals 1+, 2+, 3- |
| Connection side | field side |
| Output II | signal or error message; passive transistor output |
| Connection side | control side |
| Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2 |
| Certificate | TV 99 ATEX 1499 X |
| Output/Output | basic insulation according to IEC 62103, rated insulation voltage 50 Veff |
| EU-type examination certificate | DMT 01 ATEX E 133 |
| Configuration | via DIP switches |
| Connection | output I: terminals 7, 8 ; output II: terminals 10, 11 |
| Input | EN 60947-5-6:2000 |
| Open circuit voltage/short-circuit current | approx. 8 V DC / approx. 8 mA |
| Output I | signal, passive electronic output |
Currently, the goods have no revocation.
Your feedback will be the first to
Share your thoughts, your opinion about the product.
Thank you for your feedback. In order to leave your feedback, simply fill out the form below.