sensitivity adjustment | potentiometer, 15 turn |
GND electrode | yes |
type | rectangular |
liquids in direct contact | no |
short circuit protection | yes |
output current | < 200 mA |
detection of non-conductive media | yes |
output indicator | LED yellow |
current consumption max. (no load) | 20 mA |
mounting type | flush |
housing length | 65 mm |
housing material | PBT |
reverse polarity protection | yes |
nominal sensing distance Sn | 15 mm |
fill level detection through container | yes |
voltage drop Vd | < 1,5 VDC |
operating temperature | -25 ... +75 °C |
object detection / bulk goods | yes |
nominal sensing distance Sn adjustable | 4 ... 15 mm |
output circuit | NPN break function (NC) |
voltage supply range +Vs | 10 ... 30 VDC |
manufacter SKU | CFDK 30N3600 |
temperature drift | ± 15 % (+10 ... +70 °C) |
CFDK 30N3600 dimension | 30 mm |
protection class | IP 65 |
switching frequency | < 50 Hz |
connection types | cable, 2 m |
Currently, the goods have no revocation.
Your feedback will be the first to .
Share your thoughts, your opinion about the product.
Thank you for your feedback. In order to leave your feedback, simply fill out the form below.
-
CFAM 12P3600Vendor code: 1085In stock
nominal sensing distance Sn4 mmnominal sensing distance Sn adjustable0,5 ... 4 mmmounting typeflusho...
-
CFAM 12P3600/S14Vendor code: 1080In stock
nominal sensing distance Sn4 mmnominal sensing distance Sn adjustable0,5 ... 4 mmmounting typeflusho...
-
CFBM 20N3600Vendor code: 1092In stock
nominal sensing distance Sn10 mmnominal sensing distance Sn adjustable2 ... 10 mmmounting typeflusho...
-
CFAK 12N3140/LVendor code: 1068In stock
special typeliquid level sensor for wastewaternominal sensing distance Sn0,1 mmmounting typenon-flus...
-
CFAM 12N3600/S14Vendor code: 1084In stock
nominal sensing distance Sn4 mmnominal sensing distance Sn adjustable0,5 ... 4 mmmounting typeflusho...
-
CFDK 30P3600/S14Vendor code: 1088In stock
nominal sensing distance Sn15 mmnominal sensing distance Sn adjustable4 ... 15 mmmounting typeflusho...
-
CFAK 12P1140/LVendor code: 1087In stock
special typeliquid level sensor for wastewaternominal sensing distance Sn0,1 mmmounting typenon-flus...
-
CFDK 30P1600/S14Vendor code: 1089In stock
nominal sensing distance Sn15 mmnominal sensing distance Sn adjustable4 ... 15 mmmounting typeflusho...
-
CFAM 12N1600Vendor code: 1081In stock
nominal sensing distance Sn4 mmnominal sensing distance Sn adjustable0,5 ... 4 mmmounting typeflusho...
-
CFAK 12N1140/KS35LVendor code: 1071In stock
special typeliquid level sensor for wastewaternominal sensing distance Sn0,1 mmmounting typenon-flus...