sensitivity adjustment | potentiometer, 15 turn |
output circuit | PNP make function (NO) |
housing material | PBT |
liquids in direct contact | no |
object detection / bulk goods | yes |
mounting type | flush |
output indicator | LED yellow |
reverse polarity protection | yes |
detection of non-conductive media | yes |
CFDK 30P1600 dimension | 30 mm |
voltage supply range +Vs | 10 ... 30 VDC |
connection types | cable, 2 m |
manufacter SKU | CFDK 30P1600 |
current consumption max. (no load) | 20 mA |
protection class | IP 65 |
temperature drift | ± 15 % (+10 ... +70 °C) |
operating temperature | -25 ... +75 °C |
voltage drop Vd | < 1,5 VDC |
nominal sensing distance Sn adjustable | 4 ... 15 mm |
type | rectangular |
output current | < 200 mA |
switching frequency | < 50 Hz |
housing length | 65 mm |
short circuit protection | yes |
GND electrode | yes |
fill level detection through container | yes |
nominal sensing distance Sn | 15 mm |
Currently, the goods have no revocation.
Your feedback will be the first to .
Share your thoughts, your opinion about the product.
Thank you for your feedback. In order to leave your feedback, simply fill out the form below.
-
CFAK 12N1140/LVendor code: 1086In stock
special typeliquid level sensor for wastewaternominal sensing distance Sn0,1 mmmounting typenon-flus...
-
CFAH 30P3200/S14Vendor code: 1061In stock
special typesensor for high temperaturesnominal sensing distance Sn15 mmnominal sensing distance Sn ...
-
CFBM 20N3600Vendor code: 1092In stock
nominal sensing distance Sn10 mmnominal sensing distance Sn adjustable2 ... 10 mmmounting typeflusho...
-
CFBM 20P1600Vendor code: 1093In stock
nominal sensing distance Sn10 mmnominal sensing distance Sn adjustable2 ... 10 mmmounting typeflusho...
-
CFDM 20N1500/S35LVendor code: 1066In stock
nominal sensing distance Sn5 mmmounting typeflushGND electrodeyesoutput circuitNPN make function (NO...
-
CFAK 12N1140/KS35LVendor code: 1071In stock
special typeliquid level sensor for wastewaternominal sensing distance Sn0,1 mmmounting typenon-flus...
-
CFDK 30N1600/S14Vendor code: 1075In stock
nominal sensing distance Sn15 mmnominal sensing distance Sn adjustable4 ... 15 mmmounting typeflusho...
-
CFAM 12N3600/S14Vendor code: 1084In stock
nominal sensing distance Sn4 mmnominal sensing distance Sn adjustable0,5 ... 4 mmmounting typeflusho...
-
CFAM 12P3600/S14Vendor code: 1080In stock
nominal sensing distance Sn4 mmnominal sensing distance Sn adjustable0,5 ... 4 mmmounting typeflusho...
-
CFAK 12P3140/KS35LVendor code: 1065In stock
special typeliquid level sensor for wastewaternominal sensing distance Sn0,1 mmmounting typenon-flus...