output circuit | analog |
linearity error | ± 1,5 ... ± 4 mm |
type | rectangular |
current consumption max. (no load) | 80 mA |
response time / release time | < 3 ms |
protection class | IP 68/69K & proTect+ |
adjustment | IO-Link |
output signal | 0 ... 10 VDC |
temperature drift | < 0,1 % Sde/K |
light source | pulsed point source LED |
power on indication | LED green |
width / diameter | 19,6 mm |
output current | < 100 mA |
manufacter SKU | FADH 14U4470/IO |
wave length | 660 nm |
load resistance (analog U) | > 100 kOhm |
soiled lens indicator | LED red |
connection types | cable 4 pin, 2 m |
alarm output | push-pull |
special type | hygienic design |
measuring distance Sd | 50 ... 400 mm |
Teach-in range min. | > 20 mm |
short circuit protection | yes |
housing material | stainless steel 1.4404 (V4A) |
operating temperature | 0 ... +50 °C |
beam type | point |
depth | 34,3 mm |
front (optics) | PMMA |
voltage supply range +Vs | 14 ... 26 VDC |
beam diameter | 8 mm |
resolution | 0,1 ... 1 mm |
height / length | 52,2 mm |
reverse polarity protection | yes, Vs to GND |
Currently, the goods have no revocation.
Your feedback will be the first to .
Share your thoughts, your opinion about the product.
Thank you for your feedback. In order to leave your feedback, simply fill out the form below.
-
OADM 13I6475/S35AVendor code: 1123In stock
measuring distance Sd50 ... 350 mmadjustmentTeach-in: button / externalTeach-in range min.> 5 mmo...
-
OADM 13I7580/S35AVendor code: 1131In stock
measuring distance Sd50 ... 550 mmadjustmentTeach-in: button / externalTeach-in range min.> 10 mmope...
-
OADM 12U7460/S35AVendor code: 1148In stock
measuring distance Sd16 ... 120 mmadjustmentTeach-in: button / externalTeach-in range min.> 2 mmoper...
-
OADM 13U6575/S35AVendor code: 1142In stock
measuring distance Sd50 ... 350 mmadjustmentTeach-in: button / externalTeach-in range min.> 5 mmoper...
-
OADK 25U7480/S14CVendor code: 1166In stock
measuring distance Sd100 ... 1000 mmadjustmentTeach-inTeach-in range min.> 50 mmoperating temperatur...
-
OADM 20I6581/S14FVendor code: 1108In stock
measuring distance Sd200 ... 1000 mmadjustmentTeach-in: button / externalTeach-in range min.> 20 ...
-
OADM 20I2460/S14CVendor code: 1152In stock
measuring distance Sd30 ... 130 mmadjustmentTeach-in: button / externalTeach-in range min.> 3 mmo...
-
OADM 12I6430/S35AVendor code: 1117In stock
measuring distance Sd16 ... 26 mmadjustmentTeach-in: button / externalTeach-in range min.> 1 mmop...
-
OADM 20I5571/S14CVendor code: 1112In stock
measuring distance Sd30 ... 130 mmadjustmentnowave length650 nmoperating temperature0 ... +50 °C...
-
OADM 20I6481/S14FVendor code: 1111In stock
measuring distance Sd200 ... 1000 mmadjustmentTeach-in: button / externalTeach-in range min.> 20 ...