voltage supply range +Vs | 12 ... 36 VDC |
IR06.D03S-Q30.UA1Z.7SCV dimension | 6,5 mm |
protection class | IP 67 |
temperature drift | ± 6 % (Full Scale; -10 ... +70 °C) ± 4 % (Full Scale; 0 ... +60 °C) |
operating temperature | -10 ... +70 °C |
housing length | 30 mm |
linearity error | ± 300 µm (S = 0 ... 3 mm) ± 90 µm (S = 0,75 ... 2,25 mm) |
resolution | < 0,001 mm (stat.) < 0,01 mm (dynam.) |
connection types | cable, 2 m |
housing material | stainless steel |
load resistance | > 4000 Ohm |
manufacter SKU | IR06.D03S-Q30.UA1Z.7SCV |
response time (factory characteristic) | < 0,5 ms |
repeat accuracy | < 0,02 mm |
type | cylindrical smooth |
reverse polarity protection | yes |
output signal | 0 ... 10 VDC |
measuring distance Sd | 0 ... 3 mm |
mounting type | quasi-flush |
output circuit | voltage output |
short circuit protection | yes |
current consumption max. (no load) | 10 mA |
Currently, the goods have no revocation.
Your feedback will be the first to .
Share your thoughts, your opinion about the product.
Thank you for your feedback. In order to leave your feedback, simply fill out the form below.
-
HOG10 DN 1024 I LR 16H7 KLK-AXVendor code: 1225In stock
Incremental encoders - combination HOG 10 + KLK-AX
-
IFRD 12N37T3/S14Vendor code: 1320In stock
mounting typequasi-flushspecial typefull metal housing (DuroProx)high temperaturenominal sensing dis...
-
IWRM 30Z8704/S14CVendor code: 1230In stock
mounting typequasi-flushspecial type2 adjust. switching pointslinearizedmeasuring distance Sd0 ... 1...
-
IFRP 12P1501/S14Vendor code: 1333In stock
mounting typeflushspecial typehigh pressurenominal sensing distance Sn2 mmoutput circuitPNP make fun...
-
IWRM 30I9704/S14Vendor code: 1234In stock
mounting typequasi-flushmeasuring distance Sd0 ... 16 mmresolution< 0,005 mm (stat.)< 0,01 mm (dynam...
-
IFRP 16P1501/S14Vendor code: 1260In stock
mounting typeflushspecial typehigh pressurenominal sensing distance Sn2 mmoutput circuitPNP make fun...
-
IWRM 06I9501Vendor code: 1301In stock
mounting typequasi-flushmeasuring distance Sd0 ... 2 mmresolution< 0,001 mm (stat.)< 0,005 mm (dynam...
-
IWRM 12U9705/S14Vendor code: 1250In stock
mounting typequasi-flushmeasuring distance Sd0 ... 4 mmresolution< 0,0005 mm (stat.)< 0,001 mm (dyna...
-
IWRM 06I9501/S35Vendor code: 1321In stock
mounting typequasi-flushmeasuring distance Sd0 ... 2 mmresolution< 0,001 mm (stat.)< 0,005 mm (dynam...
-
IWFM 18L9504/S35AVendor code: 1247In stock
mounting typeflushmeasuring distance Sd0 ... 4 mmresolution< 0,005 mmoutput circuitvoltage - / cu...