load resistance +Vs max. | < 1000 Ohm |
connection types | cable, 2 m |
load resistance +Vs min. | < 500 Ohm |
output circuit | current output |
current consumption max. (no load) | 35 mA |
short circuit protection | yes |
mounting type | flush |
reference distance | 3,25 ... 3,75 mm |
measuring distance Sd | 2 ... 5 mm |
residual output ripple | < 0,5 % Vs |
measuring speed | < 1 mm / ms |
type | cylindrical threaded |
repeat accuracy | < 0,02 mm |
temperature coefficient | 1 µm / (K mm) |
output signal | 4 ... 20 mA |
manufacter SKU | IWRM 18I9501 |
reverse polarity protection | yes |
linearity error | ± 100 µm |
IWRM 18I9501 dimension | 18 mm |
operating temperature | 0 ... +60 °C |
housing material | brass nickel plated |
housing length | 65 mm |
voltage supply range +Vs | 15 ... 30 VDC |
protection class | IP 67 |
Currently, the goods have no revocation.
Your feedback will be the first to .
Share your thoughts, your opinion about the product.
Thank you for your feedback. In order to leave your feedback, simply fill out the form below.
-
IFRP 16P1501/S14Vendor code: 1260In stock
mounting typeflushspecial typehigh pressurenominal sensing distance Sn2 mmoutput circuitPNP make fun...
-
IWRM 08I9501/S35Vendor code: 1323In stock
mounting typequasi-flushmeasuring distance Sd0 ... 2 mmresolution< 0,001 mm (stat.)< 0,005 mm (dynam...
-
IFRD 18N37T3/S14Vendor code: 1283In stock
mounting typequasi-flushspecial typefull metal housing (DuroProx)high temperaturenominal sensing dis...
-
IWRM 12U9705/S14Vendor code: 1250In stock
mounting typequasi-flushmeasuring distance Sd0 ... 4 mmresolution< 0,0005 mm (stat.)< 0,001 mm (dyna...
-
IWRM 06U9501/S35Vendor code: 1331In stock
mounting typequasi-flushmeasuring distance Sd0 ... 2 mmresolution< 0,001 mm (stat.)< 0,005 mm (dynam...
-
IWRM 08U9501/S35Vendor code: 1332In stock
mounting typequasi-flushmeasuring distance Sd0 ... 2 mmresolution< 0,001 mm (stat.)< 0,005 mm (dynam...
-
IWRM 12I9704/S14Vendor code: 1264In stock
mounting typequasi-flushmeasuring distance Sd0 ... 4 mmresolution< 0,001 mm (stat.)< 0,005 mm (dynam...
-
IPRM 12I9505/S14Vendor code: 1233In stock
mounting typequasi-flushmeasuring speed< 1 mm / msmeasuring distance Sd0 ... 2 mmoutput circuitcurre...
-
IWFM 08U9501Vendor code: 1277In stock
mounting typequasi-flushmeasuring distance Sd0 ... 2 mmresolution< 0,001 mm (stat.)< 0,005 mm (dynam...
-
IWRM 18U9704/S14Vendor code: 1242In stock
mounting typequasi-flushmeasuring distance Sd0 ... 8 mmresolution< 0,005 mm (stat.)< 0,01 mm (...