Pepperl+Fuchs OCS2000-M1K-N2

Retroreflective sensor
SKU: OCS2000-M1K-N2
0.00

Out of stock

One click request

The Retroreflective sensor from Pepperl+Fuchs is designed for use in hazardous environments, providing reliable performance with ATEX and IECEX approvals for both dust and gas zones. Its glare protection and adjustable sensor head enhance flexibility and functionality in various applications.

All description
Manufacturer: Pepperl+Fuchs
Description:

The Retroreflective sensor is a key component in the family of photoelectric sensors, specifically engineered for applications that require high precision in detecting objects without direct contact. This sensor operates by reflecting a beam of light off a retroreflective target, enabling it to detect the presence or absence of objects within its sensing range. The implementation of these sensors is prevalent in material handling, packaging, and safety applications where reliable detection is critical.

Designed with intrinsic safety features, this sensor is suitable for use in potentially explosive atmospheres, classified under zone 20 for dust and zone 1 for gas. The device is equipped with a polarization filter to eliminate glare, ensuring accurate detection even in challenging lighting conditions. Additionally, the adjustable sensor head allows for customizable alignment to suit specific installation requirements, providing versatility across a range of industrial environments.

ATEX marking Zone 1: II 2G Ex ia op is IIC T6…T1 Gb
Effective internal capacitance Ci max. 1200 nF
Installation, commissioning The associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. This certificate does not guarantee that the components installed in the partition isolate the zones completely from one another. Appropriate measures must be taken when the partition is set up to ensure the zones are completely isolated.
Installation, commissioning The associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. This certificate does not guarantee that the components installed in the partition isolate the zones completely from one another. Appropriate measures must be taken when the partition is set up to ensure the zones are completely isolated.
Ambient temperature The temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate.
Switching voltage 8 V DC (Ri approx. 1 kΩ)
Applicant Pepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany
Mass 100 g
Maintenance No modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible.
EC-Type Examination Certificate PTB 01 ATEX 2203 X
Standards IEC 60079-0:2011 IEC 60079-11:2011 IEC 60079-28:2006
ATEX marking Zone 20/21: II 1D Ex ia IIIC T 135°C Da
IECEx marking Zone 1: II 2G Ex ia op is IIC T6…T1 Gb
Response time 5 ms
Installation, commissioning The associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety.
Effective detection range 0 … 2 m
Reflector distance 100 … 2000 mm
Maintenance No modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible.
General The apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The EU-type examination certificate has to be observed.
Certificate number IECEx PTB 12.0060 X
Maintenance No modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible.
Polarization filter yes
Operating voltage 6 … 20 V DC (Ri approx. 0 Ohm)
Ambient temperature The temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate.
Effective internal inductance Li negligibly small
Function indicator LED yellow: switching state
EC-Type Examination Certificate ZELM 03 ATEX 0196 X
Installation, commissioning The associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety.
Standards EN 60079-0:2012+A11:2013
EN 60079-11:2012
EN 60079-28:2007
Applicant Pepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany
Degree of protection IP67 according to EN 60529, Class II insulation
General The apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The IECEx certificate must be observed.
Housing height 30 mm
Applicant Pepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany
Product standard EN 60947-5-2
CE marking CE0102
Housing width 30 mm
General The apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The EU-type examination certificate has to be observed.
Light source LED , 660 nm
Standards IEC 60079-0:2011 IEC 60079-11:2011
Reference target Retro-reflector C110-2
Connection M16 terminal compartment, core cross section ≤ 2.5 mm2
Ambient temperature -25 … 70 °C (-13 … 158 °F)
Storage temperature -40 … 80 °C (-40 … 176 °F)
Threshold detection range 2 m
Directive conformity 2014/34/EU
MTTFd 1319 a
Effective internal inductance Li negligibly small
Applicant Pepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany
Effective internal capacitance Ci max. 75 nF
Mission Time (TM) 20 a
Ripple 5 %
Certificate number IECEx ZLM 12.0005X
Diagnostic Coverage (DC) 0 %
General The apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The IECEx certificate must be observed.
Housing depth 102 mm
Light type modulated visible red light
Signal output 1 NAMUR output NC/NO programmable
Switching frequency ≤ 100 Hz
Effective internal capacitance Ci max. 75 nF
Ambient temperature -25 … 70 °C (-13 … 158 °F)
CCC approval CCC approval / marking not required for products rated ≤36 V
Standards EN 60079-0:2012+A11:2013
EN 60079-11:2012
EN 60079-28:2007
Ambient temperature -25 … 70 °C (-13 … 158 °F)
Time delay before availability 20 ms
Effective internal inductance Li negligibly small
Switching type light/dark on, programmable
Directive conformity 2014/34/EU
Ambient light limit ≤ 10000 Lux sun light
≤ 7500 Lux halogen light
Effective internal capacitance Ci max. 1200 nF
Effective internal inductance Li negligibly small
IECEx marking Ex ia IIIC T135°C Da
CE marking CE0102
Maintenance No modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible.
Reviews
Leave feedback on the goods

Currently, the goods have no revocation.
Your feedback will be the first to
Share your thoughts, your opinion about the product.

Leave feedback

Thank you for your feedback. In order to leave your feedback, simply fill out the form below.

Thank you for your feedback. In order to leave your feedback, simply fill out the form below. “Pepperl+Fuchs OCS2000-M1K-N2”

Your email address will not be published. Required fields are marked *

Other products categories