The Retroreflective sensor from Pepperl+Fuchs is designed for use in hazardous environments, providing reliable performance with ATEX and IECEX approvals for both dust and gas zones. Its glare protection and adjustable sensor head enhance flexibility and functionality in various applications.
The Retroreflective sensor is a key component in the family of photoelectric sensors, specifically engineered for applications that require high precision in detecting objects without direct contact. This sensor operates by reflecting a beam of light off a retroreflective target, enabling it to detect the presence or absence of objects within its sensing range. The implementation of these sensors is prevalent in material handling, packaging, and safety applications where reliable detection is critical.
Designed with intrinsic safety features, this sensor is suitable for use in potentially explosive atmospheres, classified under zone 20 for dust and zone 1 for gas. The device is equipped with a polarization filter to eliminate glare, ensuring accurate detection even in challenging lighting conditions. Additionally, the adjustable sensor head allows for customizable alignment to suit specific installation requirements, providing versatility across a range of industrial environments.
| ATEX marking | Zone 1: |
| Effective internal capacitance Ci | max. 1200 nF |
| Installation, commissioning | The associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. This certificate does not guarantee that the components installed in the partition isolate the zones completely from one another. Appropriate measures must be taken when the partition is set up to ensure the zones are completely isolated. |
| Installation, commissioning | The associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. This certificate does not guarantee that the components installed in the partition isolate the zones completely from one another. Appropriate measures must be taken when the partition is set up to ensure the zones are completely isolated. |
| Ambient temperature | The temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. |
| Switching voltage | 8 V DC (Ri approx. 1 kΩ) |
| Applicant | Pepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany |
| Mass | 100 g |
| Maintenance | No modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible. |
| EC-Type Examination Certificate | PTB 01 ATEX 2203 X |
| Standards | IEC 60079-0:2011 IEC 60079-11:2011 IEC 60079-28:2006 |
| ATEX marking | Zone 20/21: |
| IECEx marking | Zone 1: |
| Response time | 5 ms |
| Installation, commissioning | The associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. |
| Effective detection range | 0 … 2 m |
| Reflector distance | 100 … 2000 mm |
| Maintenance | No modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible. |
| General | The apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The EU-type examination certificate has to be observed. |
| Certificate number | IECEx PTB 12.0060 X |
| Maintenance | No modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible. |
| Polarization filter | yes |
| Operating voltage | 6 … 20 V DC (Ri approx. 0 Ohm) |
| Ambient temperature | The temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. |
| Effective internal inductance Li | negligibly small |
| Function indicator | LED yellow: switching state |
| EC-Type Examination Certificate | ZELM 03 ATEX 0196 X |
| Installation, commissioning | The associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. |
| Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 EN 60079-28:2007 |
| Applicant | Pepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany |
| Degree of protection | IP67 according to EN 60529, Class II insulation |
| General | The apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The IECEx certificate must be observed. |
| Housing height | 30 mm |
| Applicant | Pepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany |
| Product standard | EN 60947-5-2 |
| CE marking | CE0102 |
| Housing width | 30 mm |
| General | The apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The EU-type examination certificate has to be observed. |
| Light source | LED , 660 nm |
| Standards | IEC 60079-0:2011 IEC 60079-11:2011 |
| Reference target | Retro-reflector C110-2 |
| Connection | M16 terminal compartment, core cross section ≤ 2.5 mm2 |
| Ambient temperature | -25 … 70 °C (-13 … 158 °F) |
| Storage temperature | -40 … 80 °C (-40 … 176 °F) |
| Threshold detection range | 2 m |
| Directive conformity | 2014/34/EU |
| MTTFd | 1319 a |
| Effective internal inductance Li | negligibly small |
| Applicant | Pepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany |
| Effective internal capacitance Ci | max. 75 nF |
| Mission Time (TM) | 20 a |
| Ripple | 5 % |
| Certificate number | IECEx ZLM 12.0005X |
| Diagnostic Coverage (DC) | 0 % |
| General | The apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The IECEx certificate must be observed. |
| Housing depth | 102 mm |
| Light type | modulated visible red light |
| Signal output | 1 NAMUR output NC/NO programmable |
| Switching frequency | ≤ 100 Hz |
| Effective internal capacitance Ci | max. 75 nF |
| Ambient temperature | -25 … 70 °C (-13 … 158 °F) |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
| Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 EN 60079-28:2007 |
| Ambient temperature | -25 … 70 °C (-13 … 158 °F) |
| Time delay before availability | 20 ms |
| Effective internal inductance Li | negligibly small |
| Switching type | light/dark on, programmable |
| Directive conformity | 2014/34/EU |
| Ambient light limit | ≤ 10000 Lux sun light ≤ 7500 Lux halogen light |
| Effective internal capacitance Ci | max. 1200 nF |
| Effective internal inductance Li | negligibly small |
| IECEx marking | Ex ia IIIC T135°C Da |
| CE marking | CE0102 |
| Maintenance | No modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible. |