output current | < 200 mA |
voltage drop Vd | < 2,5 VDC |
operating temperature | 0 ... +50 °C |
housing length | 39,5 mm |
mounting type | non-flush |
CFAK 12N3140/KS35L dimension | 12 mm |
liquids in direct contact | yes |
temperature drift | ± 20 % |
output indicator | LED yellow |
short circuit protection | yes |
sensitivity adjustment | no |
material (screw nut) | POM |
output circuit | NPN break function (NC) |
current consumption max. (no load) | 12 mA |
fill level detection through container | no |
voltage supply range +Vs | 10 ... 30 VDC |
material (gasket) | EPDM50 |
manufacter SKU | CFAK 12N3140/KS35L |
detection of non-conductive media | no |
type | cylindrical threaded |
GND electrode | no |
nominal sensing distance Sn | 0,1 mm |
reverse polarity protection | yes |
protection class | IP 67 |
housing material | POM |
switching frequency | < 15 Hz |
measurement type | contact with medium |
special type | liquid level sensor for wastewater |
object detection / bulk goods | no |
connection types | flylead connector M8, L=200 mm |
Currently, the goods have no revocation.
Your feedback will be the first to .
Share your thoughts, your opinion about the product.
Thank you for your feedback. In order to leave your feedback, simply fill out the form below.
-
CFDK 30N1600Vendor code: 1076In stock
nominal sensing distance Sn15 mmnominal sensing distance Sn adjustable4 ... 15 mmmounting typeflusho...
-
CFAM 12N1600Vendor code: 1081In stock
nominal sensing distance Sn4 mmnominal sensing distance Sn adjustable0,5 ... 4 mmmounting typeflusho...
-
CFDM 20P1500/S35LVendor code: 1063In stock
nominal sensing distance Sn5 mmmounting typeflushGND electrodeyesoutput circuitPNP make function (NO...
-
CFAK 12P1140/LVendor code: 1087In stock
special typeliquid level sensor for wastewaternominal sensing distance Sn0,1 mmmounting typenon-flus...
-
CFBM 20P1600Vendor code: 1093In stock
nominal sensing distance Sn10 mmnominal sensing distance Sn adjustable2 ... 10 mmmounting typeflusho...
-
CFAM 12P1600/S14Vendor code: 1073In stock
nominal sensing distance Sn4 mmnominal sensing distance Sn adjustable0,5 ... 4 mmmounting typeflusho...
-
CFDK 30N3600Vendor code: 1077In stock
nominal sensing distance Sn15 mmnominal sensing distance Sn adjustable4 ... 15 mmmounting typeflusho...
-
CFAK 12N1140/LVendor code: 1086In stock
special typeliquid level sensor for wastewaternominal sensing distance Sn0,1 mmmounting typenon-flus...
-
CFAM 12N3600Vendor code: 1083In stock
nominal sensing distance Sn4 mmnominal sensing distance Sn adjustable0,5 ... 4 mmmounting typeflusho...
-
CFBM 20P3600Vendor code: 1094In stock
nominal sensing distance Sn10 mmnominal sensing distance Sn adjustable2 ... 10 mmmounting typeflusho...