connection types | connector M12 |
type | cylindrical threaded |
CFAM 12N1600/S14 dimension | 12 mm |
reverse polarity protection | yes |
operating temperature | -25 ... +75 °C |
protection class | IP 65 |
output circuit | NPN make function (NO) |
short circuit protection | yes |
nominal sensing distance Sn | 4 mm |
current consumption max. (no load) | 20 mA |
object detection / bulk goods | yes |
liquids in direct contact | no |
fill level detection through container | yes |
housing length | 76 mm |
temperature drift | ± 15 % (+10 ... +70 °C) |
sensitivity adjustment | potentiometer, 240° |
output indicator | LED yellow |
GND electrode | yes |
voltage supply range +Vs | 10 ... 30 VDC |
voltage drop Vd | < 1,5 VDC |
manufacter SKU | CFAM 12N1600/S14 |
output current | < 200 mA |
mounting type | flush |
nominal sensing distance Sn adjustable | 0,5 ... 4 mm |
housing material | brass nickel plated |
detection of non-conductive media | yes |
switching frequency | < 50 Hz |
Currently, the goods have no revocation.
Your feedback will be the first to .
Share your thoughts, your opinion about the product.
Thank you for your feedback. In order to leave your feedback, simply fill out the form below.
-
CFAM 12N3600Vendor code: 1083In stock
nominal sensing distance Sn4 mmnominal sensing distance Sn adjustable0,5 ... 4 mmmounting typeflusho...
-
CFAM 12P3600Vendor code: 1085In stock
nominal sensing distance Sn4 mmnominal sensing distance Sn adjustable0,5 ... 4 mmmounting typeflusho...
-
CFBM 20P3600Vendor code: 1094In stock
nominal sensing distance Sn10 mmnominal sensing distance Sn adjustable2 ... 10 mmmounting typeflusho...
-
CFAM 12P1600/S14Vendor code: 1073In stock
nominal sensing distance Sn4 mmnominal sensing distance Sn adjustable0,5 ... 4 mmmounting typeflusho...
-
CFAK 12N3140/KS35LVendor code: 1064In stock
special typeliquid level sensor for wastewaternominal sensing distance Sn0,1 mmmounting typenon-flus...
-
CFAM 12N3600/S14Vendor code: 1084In stock
nominal sensing distance Sn4 mmnominal sensing distance Sn adjustable0,5 ... 4 mmmounting typeflusho...
-
CFAK 12P3140/LVendor code: 1069In stock
special typeliquid level sensor for wastewaternominal sensing distance Sn0,1 mmmounting typenon-flus...
-
CFAH 30P1200/S14Vendor code: 1062In stock
special typesensor for high temperaturesnominal sensing distance Sn15 mmnominal sensing distance Sn ...
-
CFAK 12N3140/LVendor code: 1068In stock
special typeliquid level sensor for wastewaternominal sensing distance Sn0,1 mmmounting typenon-flus...