beam type | point |
current consumption max. (no load) | 80 mA |
response time / release time | < 3 ms |
operating temperature | 0 ... +50 °C |
type | rectangular |
width / diameter | 19,6 mm |
housing material | stainless steel 1.4404 (V4A) |
depth | 34,3 mm |
output current | < 100 mA |
output circuit | analog |
reverse polarity protection | yes, Vs to GND |
wave length | 660 nm |
manufacter SKU | FADH 14I4470/IO |
protection class | IP 68/69K & proTect+ |
load resistance (analog I) | < (+Vs - 10 V) / 0,02 A |
power on indication | LED green |
measuring distance Sd | 50 ... 400 mm |
output signal | 4 ... 20 mA |
alarm output | push-pull |
resolution | 0,1 ... 1 mm |
temperature drift | < 0,1 % Sde/K |
linearity error | ± 1,5 ... ± 4 mm |
beam diameter | 8 mm |
front (optics) | PMMA |
short circuit protection | yes |
connection types | cable 4 pin, 2 m |
special type | hygienic design |
height / length | 52,2 mm |
adjustment | IO-Link |
voltage supply range +Vs | 12 ... 26 VDC |
light source | pulsed point source LED |
soiled lens indicator | LED red |
Teach-in range min. | > 20 mm |
Currently, the goods have no revocation.
Your feedback will be the first to .
Share your thoughts, your opinion about the product.
Thank you for your feedback. In order to leave your feedback, simply fill out the form below.
-
OADM 20I6472/S14FVendor code: 1120In stock
measuring distance Sd50 ... 300 mmadjustmentTeach-in: button / externalTeach-in range min.> 5 mmo...
-
OADM 20U2480/S14CVendor code: 1158In stock
measuring distance Sd100 ... 600 mmadjustmentTeach-in: button / externalTeach-in range min.> 10 mmop...
-
FADH 14I4470/KS34A/IOVendor code: 1161In stock
measuring distance Sd50 ... 400 mmspecial typehygienic designadjustmentIO-Linkoperating temperature0...
-
OADM 20I6580/S14FVendor code: 1109In stock
measuring distance Sd100 ... 600 mmadjustmentTeach-in: button / externalTeach-in range min.> 10 mmop...
-
FADH 14U4470/IOVendor code: 1164In stock
measuring distance Sd50 ... 400 mmspecial typehygienic designadjustmentIO-Linkoperating temperature0...
-
OADM 20I2460/S14CVendor code: 1152In stock
measuring distance Sd30 ... 130 mmadjustmentTeach-in: button / externalTeach-in range min.> 3 mmo...
-
OADM 13T7480/S35AVendor code: 1139In stock
measuring distance Sd50 ... 550 mmadjustmentnopower on indicationLED greenoperating temperature0 ......
-
OHDM 20P6990/S14CVendor code: 1149In stock
type background suppressionlight sourcepulsed red laser diodesensing distance Tw210 ... 1500 mmopera...
-
OADM 13S6575/S35AVendor code: 1134In stock
measuring distance Sd50 ... 350 mmadjustmentnopower on indicationLED greenoperating temperature0 ......
-
FADK 14I4470/IOVendor code: 1165In stock
measuring distance Sd50 ... 400 mmadjustmentIO-LinkTeach-in range min.> 20 mmoperating temperatur...