Out of stock
The EPV 6500 vent series offers a range of specialized vents designed for various applications, ensuring intrinsically safe operation. These vents are ideal for continuous flow outputs used in dilution, purging, and pressurization processes.
The EPV 6500 vent family is engineered to provide reliable venting solutions in environments requiring explosion protection. These vents are tailored for applications involving air or inert gas conversations, with options available for both low and high leakage rates to suit specific operational needs. Their robust design accommodates continuous flow, making them suitable for dilution applications, ensuring precise flow rates.
With a maximum enclosure size of 12.75 cubic meters (450 cubic feet), the vents support universal mounting in any orientation, allowing for flexible integration into existing systems. Certified for ATEX/IECEx Zone 1/21, these vents ensure safe operation in hazardous environments while meeting stringent safety standards, including up to SIL 2 according to IEC 61508. The EPV 6500 series is the preferred choice for industries requiring stringent safety measures and reliable performance in explosion-prone areas.
| Purge flow rate | See graphs Readout on display is in increments of 28 l/min (1 scfm). Minimum and maximum reading depends on type of vent and supply pressure. EPV-6500-*-07, 08 will readout continuous flow. |
| Breaking pressure | EPV-6500-…-01: 2.0 mbar (0.8″” wc) EPV-6500-…-03: 3.5 mbar (1.4″” wc) EPV-6500-…-05: 3.8 mbar (1.5″” wc) EPV-6500-…-07: n/a EPV-6500-…-08: n/a |
| Number of volume exchanges | 5 to 19 |
| LED indicator | POWER: green |
| Vibration resistance | 5 … 100 Hz , 1 g, 12 m/s2, all axes |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
| Storage temperature | -40 … 70 °C (-40 … 158 °F) |
| EU-Type Examination Certificate | ATEX UL / DEMKO 15 ATEX 1622X |
| Dimensions | 127 x 146 x 83 mm (5.0″” x 5.8″” x 3.3″”) |
| Relative humidity | 5 … 90 %, non-condensing |
| Shock resistance | EN 60068-2 |
| Maximum pressure | depends on the integrity of the enclosure (strength) max. vent pressure: 25” wc (635 mm wc) (62 mbar / 6200 pa) vent pressure range: 0 to 9.9″” wc (0 to 25 mbar) |
| Mass | approx. 1.4 kg (3.1 lb) |
| Degree of protection | IP66 |
| Cable length | max. 60 meters at 50 pf/ft and 0.2 �H/ft |
| Impact resistance | 30 g, 11 ms, all axes |
| Ambient temperature | -20 … 70 °C (-4 … 158 °F) |
| Purge flow and enclosure pressure rate | See graphs Readout on display is in increments of 28 l/min (1 scfm). Minimum and maximum reading depends on type of vent and supply pressure. EPV-6500-*-07, 08 will readout continuous flow. |
| Flow rate for leakage compensation | EPV-6500….-01: 593 l/hr (21 scfh) @ .63mbar (.25″”wc) 1640 l/hr (58 scfh) @ 1.9mbar (0.75″”wc) EPV-6500….-03: 395 l/hr (14 scfh) @ .63mbar (.25″”wc) 961 l/hr (34 scfh) @ 1.9mbar (0.75″”wc) EPV-6500….-05: 260 l/hr (9.2 scfh) @ .63mbar (.25″”wc) 622 l/hr (22 scfh) @ 1.9mbar (0.75″”wc) EPV-6500….-07: n/a EPV-6500….-08: n/a |
| IECEx approval | IECEx UL / DEMKO 15.0147X |
| Installation | – any orientation to enclosure – not gravity dependent – internal and external mounting possible |
| Safety Integrity Level (SIL) | SIL 2 |
| Hazardous environment | gas, dust, gas and dust |
| Series | 6500 |
| Mounting | 1 “” NPT knockout (50.8mm (2″”) hole) with seal nut included |
| Degree of protection | EN 60529 |
| Safe pressure | Gas: 0.35” wc (8,88 mm wc) (0.88 mbar/ 88 pa) Dust: 0.35” wc (8,88 mm wc) (0.88 mbar/ 88 pa) Gas+Dust: 0.35” wc (8,88 mm wc) (0.88 mbar/ 88 pa) |
| Protective gas supply | instrument grade air or inert gas |
Currently, the goods have no revocation.