Out of stock
The SMART Transmitter Power Supply is a versatile 2-channel isolated barrier designed for powering and interfacing with SMART transmitters and current sources. It operates on a 24 V DC supply and is suitable for various industrial applications.
The SMART Transmitter Power Supply is engineered to provide reliable power and signal isolation for SMART 2-wire and 3-wire transmitters, as well as 2-wire SMART current sources. This device is particularly effective in environments requiring intrinsic safety barriers, ensuring that equipment operates safely in potentially hazardous areas. It delivers an output current range of 0/4 mA to 20 mA, making it suitable for a wide array of industrial measurement and control applications.
Designed with a focus on safety and compliance, the power supply is capable of achieving up to SIL 2 in accordance with IEC 61508 standards. This makes it an ideal solution for industries where safety and functionality are paramount, including process automation, chemical processing, and oil and gas sectors. Its bus-powered operation minimizes installation complexity and enhances system efficiency.
| Certificate | CML 17 ATEX 3144X |
| Labeling | space for labeling at the front |
| Mass | approx. 140 g |
| Output signal | 0/4 … 20 mA (overload > 25 mA) |
| Dimensions | 18 x 106 x 128 mm (0.7 x 4.2 x 5 inch) |
| Electromagnetic compatibility | NE 21:2012 EN 61326-3-2:2008 |
| Connection side | control side |
| Load | 0 … 650 andOmega; |
| Rated voltage | 18 … 30 V DC bus powered via Termination Board |
| Display elements | LED |
| Ambient temperature | -20 … 60 °C (-4 … 140 °F) |
| Ripple | max. 50 andmicro;A rms |
| Coding | pin 1 and 3 trimmed For further information see system description. |
| Input signal | 0/4 … 20 mA , current limit 27 mA |
| Safety Integrity Level (SIL) | SIL 2 |
| Signal type | Analog input |
| Mounting | on Termination Board |
| IECEx approval | IECEx CML 17.0072X |
| Equipment | SL2: 5a(+), 5b, 7a(-); 1a(+), 1b, 3b(-) |
| Power dissipation | 1.4 W |
| Equipment | SL2: 5b(+), 7a(-); 1b(+), 3b(-) |
| Input resistance | max. 265 andOmega; SL2: 5b, 7a; 1b, 3b ; max. 330 andOmega; SL2: 5a, 7a; 1a, 3b |
| Output/Output | functional insulation, rated insulation voltage 50 V AC |
| Frequency range | field side into the control side: band width with 1 Vpp signal 0 … 7.5 kHz (-3 dB) safe area to hazardous area: band width with 1 VSS signal 0.3 … 7.5 kHz (-3 dB) |
| Rise time/fall time | 100 micro/s |
| Degree of protection | IP20 |
| Deviation | at 20 °C (68 °F), 0/4 … 20 mA 10 andmicro;A incl. calibration, linearity, hysteresis, loads and fluctuations of supply voltage |
| Connection | SL2: 5a(+), 5b, 7a(-); 1a(+), 1b, 3b(-) |
| Degree of protection | IEC 60529:2001 |
| Equipment | SL2: 5a(+), 5b(-); 1a(+), 1b(-) |
| Settling time | 200 micro/s |
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| Ripple | within the supply tolerance |
| Available voltage | 16 V at 20 mA , SL2: 5a(+), 5b(-); 1a(+), 1b(-) |
| Connection side | field side |
| Connection | SL1: 1a(-), 1b(-); 2a(+), 2b(+) |
| Relative humidity | 5 … 90 %, non-condensing up to 35 °C (95 °F) |
| Power consumption | 2.6 W |
| EU-Type Examination Certificate | CML 17 ATEX 2143X |
| Connection | SL1: 8a(+), 7a(-); 10a(+), 9a(-) |
| Output/power supply | functional insulation, rated insulation voltage 50 V AC |