Out of stock
The Universal Temperature Converter is a versatile 1-channel signal conditioner designed for various input types including thermocouples, RTDs, potentiometers, and voltage inputs. It features a 24 V DC supply and provides a current output range of 0/4 mA to 20 mA, configurable via PACTware.
The Universal Temperature Converter is part of the Pepperl+Fuchs Intrinsic Safety Barriers product family, which is essential for ensuring safe operation in hazardous environments. These devices are commonly used in industrial applications where temperature measurements are critical, allowing for accurate and reliable signal conditioning from multiple sensor types.
With integrated features like line fault detection (LFD) and sensor burnout detection, the Universal Temperature Converter enhances system reliability and safety. It supports both sink and source modes for current output, making it adaptable to various system requirements. Additionally, compliance with safety standards up to SIL 2 according to IEC 61508/IEC 61511 ensures that this device meets rigorous safety and performance criteria, making it suitable for use in process automation and control applications.
| Safety Integrity Level (SIL) | SIL 2 |
| Connection | screw terminals |
| Thermocouples | type B, E, J, K, N, R, S, T (IEC 584-1: 1995) type L (DIN 43710: 1985) type TXK, TXKH, TXA (P8.585-2001) |
| Signal type | Analog input |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
| Reaction time | worst case value (sensor breakage and/or sensor short circuit detection enabled) mV: 1 s, thermocouples with CJC: 1.1 s, thermocouples with fixed reference temperature: 1.1 s, 3- or 4-wire RTD: 920 ms, 2-wire RTD: 800 ms, Potentiometer: 2.05 s |
| Mass | approx. 100 g |
| Programming interface | programming socket |
| Ripple | within the supply tolerance |
| Potentiometer | 0 … 20 kandOmega; (2-wire connection), 0.8 … 20 kandOmega; (3-wire connection) |
| Dimensions | 12.5 x 114 x 124 mm (0.5 x 4.5 x 4.9 inch) , housing type A2 |
| Input/Other circuits | basic insulation according to IEC 61010-1, rated insulation voltage 300 Veff |
| Degree of protection | IEC 60529:2001 |
| Degree of protection | IP20 |
| Input resistance | 1 MandOmega; (-100 … 100 mV) |
| Output/supply, programming input | functional insulation, rated insulation voltage 50 V AC There is no electrical isolation between the programming input and the supply. The programming cable provides galvanic isolation so that ground loops are avoided. |
| Connection | terminals 1, 2, 3, 4 |
| Rated voltage | 19 … 30 V DC |
| Connection side | control side |
| RTD | type Pt10, Pt50, Pt100, Pt500, Pt1000 (EN 60751: 1995) type Pt10GOST, Pt50GOST, Pt100GOST, Pt500GOST, Pt1000GOST (6651-94) type Cu10, Cu50, Cu100 (P50353-92) type Ni100 (DIN 43760) |
| Electromagnetic compatibility | NE 21:2011 |
| Power dissipation/power consumption | 0.98 W / 0.98 W |
| Configuration | via PACTware |
| Display elements | LEDs |
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| Voltage | selectable within the range -100 … 100 mV |
| Connection | terminals 9+, 10- or power feed module/Power Rail |
| Labeling | space for labeling at the front |
| Connection | terminal 5: source (-), terminal 6: source (+), terminal 7: sink(-), terminal 8: sink (+) |
| Output | Analog current output |
| Connection side | field side |
| Ambient temperature | -20 … 60 °C (-4 … 140 °F) |