Out of stock
The Universal Temperature Converter is a highly versatile 1-channel isolated barrier designed for industrial applications requiring temperature measurement. It supports various input types including thermocouples, RTDs, potentiometers, and voltage inputs, making it suitable for diverse sensing applications.
The Universal Temperature Converter is an essential component in the field of intrinsic safety barriers, enabling safe temperature signal processing in hazardous environments. This device is engineered to provide accurate conversion of temperature signals to a standardized output, ensuring reliable data transmission for monitoring and control systems. With its capability to accept inputs from different sensor types, it offers significant flexibility in process automation.
Common applications of this temperature converter include process industries such as oil and gas, chemical manufacturing, and power generation, where precise temperature measurement is critical for operational safety and efficiency. The device features a configurable output ranging from 0/4 mA to 20 mA, allowing it to be set in either sink or source mode to accommodate various control system requirements. Additionally, its compatibility with PACTware for configuration enhances usability, while integrated line fault detection and sensor burnout detection provide advanced monitoring capabilities.
| Certificate | BASEEFA 13 ATEX 0103 X |
| Mass | approx. 100 g |
| Signal type | Analog input |
| Output | Analog current output |
| Degree of protection | IP20 |
| EU-Type Examination Certificate | BASEEFA 13 ATEX 0102 X |
| Connection | terminals 9+, 10- or power feed module/Power Rail |
| Dimensions | 12.5 x 114 x 124 mm (0.5 x 4.5 x 4.9 inch) , housing type A2 |
| RTD | type Pt10, Pt50, Pt100, Pt500, Pt1000 (EN 60751: 1995) type Pt10GOST, Pt50GOST, Pt100GOST, Pt500GOST, Pt1000GOST (6651-94) type Cu10, Cu50, Cu100 (P50353-92) type Ni100 (DIN 43760) |
| Programming interface | programming socket |
| IECEx approval | IECEx BAS 13.0057X |
| Connection side | field side |
| Electromagnetic compatibility | NE 21:2011 |
| Configuration | via PACTware |
| Degree of protection | IEC 60529:2001 |
| Reaction time | worst case value (sensor breakage and/or sensor short circuit detection enabled) mV: 1 s, thermocouples with CJC: 1.1 s, thermocouples with fixed reference temperature: 1.1 s, 3- or 4-wire RTD: 920 ms, 2-wire RTD: 800 ms, Potentiometer: 2.05 s |
| Input resistance | 1 MandOmega; (-100 … 100 mV) |
| Ambient temperature | -20 … 60 °C (-4 … 140 °F) |
| Connection side | control side |
| Ripple | within the supply tolerance |
| Connection | screw terminals |
| Display elements | LEDs |
| Thermocouples | type B, E, J, K, N, R, S, T (IEC 584-1: 1995) type L (DIN 43710: 1985) type TXK, TXKH, TXA (P8.585-2001) |
| Rated voltage | 19 … 30 V DC |
| Labeling | space for labeling at the front |
| Connection | terminals 1, 2, 3, 4 |
| Connection | terminal 5: source (-), terminal 6: source (+), terminal 7: sink(-), terminal 8: sink (+) |
| Voltage | selectable within the range -100 … 100 mV |
| Inputs | terminals 1, 2, 3, 4 |
| Output/supply, programming input | functional insulation, rated insulation voltage 50 V AC There is no electrical isolation between the programming input and the supply. The programming cable provides galvanic isolation so that ground loops are avoided. |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
| Protection against electrical shock | UL 61010-1:2004 |
| Potentiometer | 0 … 20 kandOmega; (2-wire connection), 0.8 … 20 kandOmega; (3-wire connection) |
| Safety Integrity Level (SIL) | SIL 2 |
| Power dissipation/power consumption | 0.98 W / 0.98 W |