The Switch Amplifier is a robust 2-channel isolated barrier designed for use in hazardous environments. With a 230 V AC supply, it supports both dry contact and NAMUR inputs, ensuring versatility in various applications.
The Switch Amplifier from Pepperl+Fuchs represents a critical component in the field of intrinsic safety barriers, enabling reliable signal transmission in hazardous areas. This device is engineered to offer high levels of isolation between the input and output, ensuring that any faults in the field wiring do not pose a risk to the safety of the overall system.
Commonly used in industrial automation and process control applications, the Switch Amplifier provides passive transistor outputs that are non-polarized, making it suitable for a variety of control scenarios. The device also features line fault detection (LFD) capabilities, enhancing safety by monitoring the integrity of the connections. With a reversible mode of operation and compliance with SIL 2 according to IEC 61508 standards, this amplifier is well-suited for demanding operational environments.
| Rated voltage | 207 … 253 V AC, 45 … 65 Hz |
| Power consumption | max. 1.5 W |
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| Connection | screw terminals |
| Safety Integrity Level (SIL) | SIL 2 |
| Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2 |
| Connection | output I: terminals 7, 8 ; output II: terminals 8, 9 |
| Ambient temperature | -20 … 60 °C (-4 … 140 °F) |
| Power dissipation | 1 W |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
| Output I, II | signal ; electronic output, passive |
| Output/power supply | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
| Input/power supply | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
| Signal type | Digital Input |
| Labeling | space for labeling at the front |
| Line fault detection | breakage I 0.1 mA , short-circuit I > 6 mA |
| Switching voltage | max. 40 V |
| Switching point/switching hysteresis | 1.2 … 2.1 mA / approx. 0.2 mA |
| Electromagnetic compatibility | NE 21:2012 |
| Switching frequency | 5 kHz |
| Mass | approx. 150 g |
| Switching current | max. 100 mA , short-circuit protected |
| Signal level | 1-signal: switching voltage – 2.5 V max. at 10 mA switching current or 3 V max. at 100 mA switching current 0-signal: switched off (off-state current 10 andmicro;A) |
| Open circuit voltage/short-circuit current | approx. 8 V DC / approx. 8 mA |
| Connection side | control side |
| Output/Output | not available |
| Control elements | DIP-switch |
| Connection | terminals 1+, 2+, 3-; 4+, 5+, 6- |
| Input/Output | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
| Rated values | acc. to EN 60947-5-6 (NAMUR), see system description for electrical data |
| Degree of protection | IP20 |
| Configuration | via DIP switches |
| Connection | terminals 14, 15 |
| EU-Type Examination Certificate | PTB 98 ATEX 2164 |
| Display elements | LEDs |
| Connection side | field side |
| Degree of protection | IEC 60529 |