Out of stock
The RTD Converter is a versatile 1-channel isolated barrier designed for use in demanding industrial environments. It supports 24 V DC supply and is compatible with 2- or 3-wire Pt100 RTD inputs, providing a reliable output of 4 mA to 20 mA with selectable temperature linearization.
The RTD Converter is part of a specialized family of intrinsic safety barriers that enable safe temperature measurement in hazardous areas. These devices are crucial for applications where temperature control and monitoring are essential, such as in chemical processing, oil and gas, and other industrial sectors that require stringent safety measures. The isolated barrier design ensures that any potential faults in the measurement circuit do not affect the overall safety of the system.
This converter is particularly beneficial in scenarios that demand high accuracy and reliability. By integrating features like DIP switch selectable ranges and sensor breakage detection, it enhances operational efficiency and reduces the risk of failure in temperature measurements. The ability to utilize both 2- and 3-wire Pt100 RTD inputs allows for flexibility in sensor configuration, making the RTD Converter a suitable choice for various applications across different industries.
| Input/Output | available |
| Lead resistance | max. 100 andOmega; per line |
| Control elements | DIP-switch rotary switch |
| Connection | screw terminals |
| Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2 |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
| Mass | approx. 150 g |
| Insulation coordination | EN 50178 |
| Degree of protection | IEC 60529 |
| Signal type | Analog input |
| Connection side | control side |
| Measurement range | span without linearization 25 … 800 °C (77 … 1472 °F)/with linearization 25 … 375 °C (77 … 707 °F), both adjustable zero point without linearization -200 … 400 °C (-328 … 752 °F)/with linearization -30 … 375 °C (-22 … 707 °F), both adjustable |
| Galvanic isolation | EN 50178 |
| Current output | 4 … 20 mA , limited to 35 mA |
| Configuration | via DIP switches via rotary switch |
| Connection | terminals 1, 2-, 3+ suitable for Pt100, 2- and 3-wire connection |
| Certificate | TV 01 ATEX 1777 X |
| Connection | terminals 9+, 8- |
| Power dissipation | 0.4 W |
| Ambient temperature | -20 … 60 °C (-4 … 140 °F) |
| Load | (U -12 V) / 0.02 A |
| Measuring current | approx. 1 mA |
| Fault signal | upscaling 22 mA (limited to 35 mA) |
| Labeling | space for labeling at the front |
| EU-Type Examination Certificate | ZELM 00 ATEX 0036 |
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| Rated voltage | 12 … 35 V DC loop powered |
| Degree of protection | IP20 |
| Connection side | field side |
Currently, the goods have no revocation.
Your feedback will be the first to
Share your thoughts, your opinion about the product.
Thank you for your feedback. In order to leave your feedback, simply fill out the form below.