Pepperl+Fuchs LUC-M10

Ultrasonic Level Sensor
SKU: LUC-M10
0.00

Out of stock

One click request

The Ultrasonic Level Sensor offers a reliable solution for non-contact level measurement in various applications. With a measuring range of up to 5 m for fluids and 2 m for bulk materials, this sensor is designed for optimal performance in demanding environments.

All description
Manufacturer: Pepperl+Fuchs
Description:

The Ultrasonic Level Sensor is engineered to provide precise level measurement without the need for direct contact with the material being measured. This makes it ideal for a wide range of applications, including liquid storage tanks, silos, and other bulk material handling systems. The device utilizes ultrasonic sound waves to determine the distance to the surface of the material, ensuring accurate readings across various conditions.

One of the key features of this sensor is its integrated temperature sensor, which automatically compensates for temperature-induced variations in sound velocity, enhancing measurement accuracy. Additionally, the sensor supports quick and straightforward commissioning through a user-friendly menu-guided interface displayed on a four-line screen. For flexibility, an optional remote display and operation capability allows users to monitor measurements from distances of up to 20 m from the transmitter, making it suitable for installations in hazardous or hard-to-reach locations.

Measuring method The sensor of the device transmits ultrasonic pulses in the direction of the product surface. There, the ultrasonic pulses are reflected back and received by the sensor. The device measures the time between pulse transmission and reception. The instrument uses the time (and the velocity of sound) to calculate the distance between the sensor membrane and the product surface. As the device knows the empty distance from a user entry, the device calculate the level.
Equipment architecture 4 … 20 mA output with HART protocol
system integration via PROFIBUS PA
Construction type compact device
Series LUC-M10
Connection terminal compartment:
In the F12 housing, the terminals are located underneath the housing cover, in the T12 housing, they are under the cover of the separate terminal compartment.
cable gland: M20x1.5 (recommended cable diameter 6 … 10 mm (0.24 … 0.4 inch))
cable entry G1/2 or NPT1/2
PROFIBUS PA: M12 plug connector
Rated voltage 2-wire HART (standard):
– current consumption 4 … 20 mA
– min. terminal voltage 14 V (at 4 mA), 8 V (at 20 mA)
– max. terminal voltage 36 V
4-wire HART:
– DC version: voltage 10.5 … 32 V, max. load 600 Ω
– AC version: 90 … 253 V, max. load 600 Ω
PROFIBUS PA: 9 … 32 V DC
for additional information see technical information
Ripple HART: 47 … 125 Hz , Upp = 200 mV (measured at 500 Ω)
Noise HART: 0.5 … 10 kHz , Urms = 2.2 mV (measured at 500 Ω)
Current consumption 2-wire devices:
– HART: 3.6 … 22 mA
– PROFIBUS PA: max. 13 mA
Power consumption 2-wire: 51 … 800 mW
4-wire AC: max. 4 VA
4-wire DC: 330 … 830 mW
Measured variable distance between the sensor membrane and the product surface
using the linearization function, the device calculate
– level in any units
– volume in any units
– flow across measuring weirs or open channels in any units
Measurement range max. 5 m (16.4 foot) in fluids
max. 2 m (6.6 foot) in bulk materials
Operating frequency approx. 70 kHz
Blocking distance 0.25 m
Load min. 250 Ω for HART communication
Linearity The linearization function of the device allows conversion of the measured value into any unit of length or volume. In open channels or measuring weirs, also a flow linearization is possible (calculation of the flow from the measured level).
Output signal according to the instrument version:
– 4 … 20 mA with HART protocol
– PROFIBUS PA
Output damping 0 … 255 s , freely selectable
Signal on alarm error information can be accessed via the following interfaces:
– on-site display (error symbol, error code and plain text description)
– current output (configurable)
– digital interface
Output/power supply at 4-wire devices with evaluation electronics and mains voltage
Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2006 , EN 61326-2-3:2006 , EN 61326-2-5:2006
Low voltage
Directive 2014/35/EU EN 61010-1:2001
Electromagnetic compatibility NE 21
Degree of protection IEC 60529:2001
Vibration resistance EN 60068-2-64
Climate class EN 60068-2-38 (test Z/AD) DIN/IEC 68 T2-30Db
Resistance to alternating temperature cycles EN 60068-2-14
Reaction time depends on the parameter settings:
– min. 0.5 s for 4-wire devices
– min. 2 s for 2-wire devices
Reference operating conditions temperature = 20 °C (68 °F)
pressure = 1013 mbarabs
humidity = 50 %
ideal reflective surface (e. g. calm, smooth fluid surface)
no interference reflections within signal beam
set application parameters:
– tank shape = flat ceiling
– medium property = liquid
– process conditions = calm surface
Measured value resolution 1 mm
Measuring frequency 2-wire devices: max. 0.5 Hz
4-wire devices: max. 2 Hz
dependent on the type of device and the parameter settings
Maximum measured error typical specifications for reference operating conditions (include linearity, repeatability, and hysteresis):
� 2 mm (0.08 inch) or 0.2% of set measuring range (empty calibration)1)
1)
whichever is greater
Installation conditions see technical information (TI)
Ambient conditions
Resistance to alternating temperature cycles Nb test: +80 °C/- 40 °C (353 K/233 K), 1 K/min, 100 cycles
Vibration resistance 20 … 2000 Hz, 1 (m/s2)2/Hz; 3 x 100 min
Process conditions
Process temperature -40 … 80 °C (-40 … 176 °F)
Process pressure (static pressure) 0.7 … 3 bar (10.2 … 43.5 psi) , absolute pressure
Ambient temperature -40 … 80 °C (-40 … 176 °F)
see technical information (TI)
Storage temperature -40 … 80 °C (-40 … 176 °F)
Degree of protection with closed housing, tested according to
– IP68, NEMA 6P (24 h at 1.83 m under water surface)
– IP66, NEMA 4X
with open housing: IP20, NEMA 1 (also ingress protection of the display)
Connection cable gland M20x1.5
cable gland NPT1/2
cable gland G1/2
PROFIBUS PA plug M12x1
Material material in contact with process: sensor PVDF, seal EPDM
housing: aluminum, seawater resistant, chromated, powder-coated
cover:
– aluminum, for version without on-site display
– inspection glass for version with on-site display
Mass 2.5 kg
Dimensions see section dimensions
Process connection – cylindrical thread G1-1/2B, G2B to DIN/ISO 228/1
– conical thread NPT1-1/2, NPT2 to ANSI B 1.20.1
– flanges to EN 1092-1 from DN80, to ANSI B 16.5 from 3 inch, to JIS B 2238 (RF) from DN80
– mounting bracket LUC-Z17
EU-type examination certificate see instruction manuals (SI)
Directive conformity
Directive 2014/34/EU EN 60079-0:2006 , EN 60079-1:2004 , EN 60079-7:2003 , EN 60079-11:2007 , EN 60079-18:2005 , EN 60079-26:2004 , EN 60079-27:2007 , EN 61241-0:2006 , EN 61241-1:2004+C11:2006
Construction type housing design:
– F12 housing with sealed terminal compartment for standard or EEx ia applications
– T12 housing with separate terminal compartment and flameproof encapsulation
cover:
– version without on-site display
– version with on-site display (transparent cover), this version cannot be supplied together with the ATEX II 1/2D certificate
Display elements display and operating module LUC-Z15 at the device
Control elements on-site operation:
– via 3 keys of the display and operating module
– via handheld terminal
remote control:
– operation with operating program (for communication variants HART or PROFIBUS-PA)
Supplementary documentation technical information (TI)
manuals, brief instructions (BA, KA)
instruction manuals (SI)
control drawings (ZD)
Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Designation – LUC-Z18, mounting bracket
– LUC-Z2*, cantilever
– LUC-Z3*, mounting frame
– LUC-Z5*, wall bracket
– LUC-Z-A**N**, adapter flange with conical thread
– LUC-Z-F**G**, adapter flange with metrical thread
– LUC-Z15, display and operating module for on-site operation
– LUC-Z16, weather protection cover
– LUC-Z40-**1*, remote display and operation
ECLASS 13.0 27200506
ECLASS 12.0 27200506
ECLASS 11.0 27200506
ECLASS 10.0.1 27200506
ECLASS 9.0 27200506
ECLASS 8.0 27200506
ECLASS 5.1 27200506
ETIM 9.0 EC003001
ETIM 8.0 EC003001
ETIM 7.0 EC003001
ETIM 6.0 EC003001
ETIM 5.0 EC001447
UNSPSC 12.1 41111950
Reviews
Leave feedback on the goods

Currently, the goods have no revocation.
Your feedback will be the first to
Share your thoughts, your opinion about the product.

Leave feedback

Thank you for your feedback. In order to leave your feedback, simply fill out the form below.

Thank you for your feedback. In order to leave your feedback, simply fill out the form below. “Pepperl+Fuchs LUC-M10”

Your email address will not be published. Required fields are marked *

Other products categories