Pepperl+Fuchs LVL-A7-BG1A-E5V1-CG-EMS

Vibration Limit Switch
SKU: LVL-A7-BG1A-E5V1-CG-EMS
0.00

Out of stock

One click request

The Vibration Limit Switch is engineered for precise monitoring of liquids in various industrial applications. Its robust design ensures reliability in challenging environments, making it suitable for process temperatures up to 150 °C (302 °F).

All description
Manufacturer: Pepperl+Fuchs
Description:

The Vibration Limit Switch is a critical component in industrial sensor technology, designed specifically for applications involving liquids. This device operates on the principle of detecting vibrations within a fluid environment, providing essential feedback for safety and operational efficiency. Its durable stainless steel housing ensures longevity and resistance to harsh conditions, making it ideal for use in various sectors including chemical processing, oil and gas, and water treatment.

With a process connection of G1/2, the switch integrates seamlessly into existing systems, allowing for straightforward installation and maintenance. The ability to conduct onsite function checks through LED indicators simplifies diagnostics, while an external function test with a test magnet enhances operational reliability. This combination of features not only meets the demands of high-temperature environments but also ensures that the system remains responsive to changes in liquid levels, thus safeguarding processes from potential failures.

Rated voltage 10 … 35 V DC
Hysteresis max. 3 mm
Output type switch output
Measuring method The tuning fork is brought to its resonance frequency by means of a piezoelectric drive. If the tuning fork is covered by liquid, this frequency changes. The electronics monitor the resonance frequency and indicate whether the tuning fork is freely vibrating or is covered by liquid.
Vibration resistance EN 60068-2-64
Measurement range min. 0.7 g/cm3
Measuring frequency approx. 1100 Hz in air
Residual ripple 5 V ss at 0 … 400 Hz
Material process connection and short tube: stainless steel 316L (1.4401/1.4435)
tuning fork: stainless steel 316L
housing cover and connector: PPSU
Process connection thread G1/2 to ISO 228
Designation see technical information (TI)
Degree of protection IEC 60529
Display elements The LED display is on the connection side.
– green LED: indication of ready to operate
– red LED: fault indication
– yellow LED: operating mode indication
Construction type compact device
Influence of medium temperature -25 andmicro;m/°C
CSA approval cCSAus Listed, General Purpose
Climate class DIN EN 60068-2-38/IEC 68-2-38
Reference operating conditions – ambient temperature: 25 °C (+77 °F)
– process pressure: 1 bar (14.5 psi)
– fluid: water (density: approx. 1 g/cm3, viscosity: 1 mm2/s)
– medium temperature: 25 °C (+77 °F)
– density setting: > 0.7 g/cm3
– switching time delay: standard (0,5 s, 1 s)
Connection This device may be used with any sequential circuit, as long as the circuit can support the electrical circuit values of the switching elements.
Current consumption < 15 mA
Non-repeatability � 1 mm acc. to DIN 61298-2
Measured variable density
Power consumption 975 mW
Supplementary documentation technical information (TI)
manual (BA)
approval (ZE)
Switch-on delay max. 3 s
Measured value resolution < 0.5 mm
Switching current max. 250 mA
Influence of medium pressure -20 andmicro;m/bar
Supplementary information Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Degree of protection IP65/IP67 , NEMA 4X
Shock resistance EN 60068-2-27
Surface quality Ra < 3.2 andmicro;m
Fusing external 500 mA slow
Switching point 13 mm � 1 mm
Switching time – 0.5 s when tuning fork is covered
– 1.0 s when tuning fork is uncovered
Connection M12 connector, 4-pin
Electromagnetic compatibility NE 21
Function test function test with test magnet (optional accessory)
Influence of ambient temperature negligible
Overspill protection see approval (ZE)
Operating mode MAX = maximum safety:
The device keeps the electronic switch closed as long as the liquid level is below the fork.
example application: overspill protection
MIN = minimum safety:
The device keeps the electronic switch closed as long as the fork is immersed in liquid.
example application: dry running protection of pumps
The electronic switch opens if the limit is reached, if a fault occurs or in the event of a power fails (quiescent current principle)
Mass approx. 140 g
Reviews
Leave feedback on the goods

Currently, the goods have no revocation.
Your feedback will be the first to
Share your thoughts, your opinion about the product.

Leave feedback

Thank you for your feedback. In order to leave your feedback, simply fill out the form below.

Thank you for your feedback. In order to leave your feedback, simply fill out the form below. “Pepperl+Fuchs LVL-A7-BG1A-E5V1-CG-EMS”

Your email address will not be published. Required fields are marked *

Other products categories