Out of stock
- Sensor head bidirectional and rotatable
- 40 mm non-flush
Inductive proximity sensors are essential components in various automation and control applications, utilizing electromagnetic fields to detect the presence of metallic objects without physical contact. These sensors are widely used in industrial environments for position sensing, object detection, and counting applications, offering high reliability and durability in demanding conditions.
The sensor’s bidirectional and rotatable head design allows for flexible installation and precise alignment in different orientations, enhancing its versatility in diverse setups. With a non-flush mounting design, these sensors are capable of detecting objects at a distance, making them suitable for applications where space is limited or where traditional sensing methods may be impractical. Common applications include material handling, assembly lines, and robotic systems, where accurate detection and feedback are critical for operational efficiency.
| Output type | NAMUR |
| Reverse polarity protection | reverse polarity protected |
| UL approval | cULus Listed, General Purpose |
| Effective internal inductivity | max. 165 nF A cable length of 10 m is considered. |
| Installation | non-flush |
| Storage temperature | -40 … 100 °C (-40 … 212 °F) |
| CE marking | [*PD-Z02586A*] |
| Reduction factor r304 | 0.75 |
| Rated operating distance | 40 mm |
| Reduction factor rBrass | 0.46 |
| Effective internal inductance | max. 130 andmicro;H A cable length of 10 m is considered. |
| Equipment protection level | Ga , Gb , Gc (ic) , Da , Mb |
| Effective internal inductance | max. 130 andmicro;H A cable length of 10 m is considered. |
| Type of protection | intrinsic safety |
| Switching state indicator | LED, yellow |
| Effective internal inductance | max. 130 andmicro;H A cable length of 10 m is considered. |
| Sensing face | PA |
| Connection type | screw terminals |
| Effective internal inductivity | max. 165 nF A cable length of 10 m is considered. |
| Type of protection | intrinsic safety |
| Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. |
| Type of protection | intrinsic safety |
| Use in the hazardous area | see instruction manuals |
| Effective internal inductance | max. 130 andmicro;H A cable length of 10 m is considered. |
| Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW : 89 °C (192.2 °F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW : 74 °C (165.2 °F) |
| Type of protection | intrinsic safety |
| Type of protection | intrinsic safety |
| Reduction factor rCu | 0.38 |
| Assured operating distance | 0 … 32.4 mm |
| CE marking | [*PD-Z02585A*] |
| Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 20 V , Ii = 25 mA , Pi = 34 mW , T6 : 66 °C (150.8 °F) T5 : 81 °C (177.8 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 20 V , Ii = 25 mA , Pi = 64 mW , T6 : 66 °C (150.8 °F) T5 : 81 °C (177.8 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 20 V , Ii = 52 mA , Pi = 169 mW , T6 : 45 °C (113 °F) T5 : 60 °C (140 °F) T4 : 89 °C (192.2 °F) T3 : 89 °C (192.2 °F) T2 : 89 °C (192.2 °F) T1 : 89 °C (192.2 °F) at Ui = 20 V , Ii = 76 mA , Pi = 242 mW , T6 : 30 °C (86 °F) T5 : 45 °C (113 °F) T4 : 74 °C (165.2 °F) T3 : 74 °C (165.2 °F) T2 : 74 °C (165.2 °F) T1 : 74 °C (165.2 °F) |
| CE marking | [*PD-Z02585A*] |
| Short-circuit protection | yes |
| Effective internal inductivity | max. 165 nF A cable length of 10 m is considered. |
| Reduction factor rAl | 0.41 |
| Ambient temperature | -25 … 100 °C (-13 … 212 °F) |
| Switching function | Normally closed (NC) |
| Core cross-section | up to 2.5 mm2 |
| Effective internal inductivity | max. 165 nF A cable length of 10 m is considered. |
| CCC approval | CCC approval / marking not required for products rated 36 V |
| Information for connection | A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 % |
| Housing base | plastic |
| Effective internal inductance | max. 130 andmicro;H A cable length of 10 m is considered. |
| Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW : 89 °C (192.2 °F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW : 74 °C (165.2 °F) |
| Switching frequency | 0 … 100 Hz |
| Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW , T6 : 73 °C (163.4 °F) T5 : 88 °C (190.4 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW , T6 : 66 °C (150.8 °F) T5 : 81 °C (177.8 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW , T6 : 45 °C (113 °F) T5 : 60 °C (140 °F) T4 : 89 °C (192.2 °F) T3 : 89 °C (192.2 °F) T2 : 89 °C (192.2 °F) T1 : 89 °C (192.2 °F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW , T6 : 30 °C (86 °F) T5 : 45 °C (113 °F) T4 : 74 °C (165.2 °F) T3 : 74 °C (165.2 °F) T2 : 74 °C (165.2 °F) T1 : 74 °C (165.2 °F) |
| Nominal voltage | 8.2 V |
| Hysteresis | 2 … 20 typ. 10 % |
| CE marking | [*PD-Z02585A*] |
| Output type | 2-wire |
| Effective internal inductivity | max. 165 nF A cable length of 10 m is considered. |
| Degree of protection | IP67 / IP69K |
| Housing material | PA |
Currently, the goods have no revocation.
Your feedback will be the first to
Share your thoughts, your opinion about the product.
Thank you for your feedback. In order to leave your feedback, simply fill out the form below.