The inductive sensors from Pepperl+Fuchs are designed for non-contact detection of metallic objects, making them ideal for various industrial automation applications. Part of the Comfort series, these sensors utilize electromagnetic fields to accurately sense the presence or absence of metal within their operational range. Their robust construction and advanced sensing technology ensure high reliability and durability in demanding environments.

Common applications for these inductive proximity sensors include position sensing, object counting, and automation tasks in manufacturing and assembly lines. They are particularly beneficial in environments where traditional mechanical switches may fail due to wear and tear. The sensors are available in various configurations to accommodate different installation requirements and operational needs, ensuring versatility across a wide range of industries.

ATEX marking II 3G Ex ic IIC T6andhellip;T1 Gc
The Ex-significant identification is on the enclosed adhesive label
Nominal voltage 8 V
ATEX marking II 3D Ex tc IIIC T80°C Dc
The Ex-related marking can also be printed on the enclosed label.
Effective internal inductance Li max. 100 andmicro;H ; A cable length of 10 m is considered.
Standards EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection “”Intrinsic safety””
Use is restricted to the following stated conditions
Effective internal inductance max. 100 andmicro;H ; a cable length of 10 m is considered.
Sensing face PBT
General The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction!
The special conditions must be observed!
The ATEX Directive applies only to the use of apparatus under atmospheric conditions.
If you use the device outside atmospheric conditions, consider that the permissible safety parameters should be reduced.
Switching state indicator all direction LED, yellow
Reverse polarity protection reverse polarity protected
EAC conformity TR CU 012/2011
Rated operating distance 5 mm
Reduction factor r304 0.74
Ambient temperature Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1.
CE marking [*PD-Z02586A*]
ATEX marking II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label.
MTTFd 2040 a
Appropriate type NCB5-18GM…-N0…
Effective internal capacitance max. 95 nF ; a cable length of 10 m is considered.
ATEX marking II 3D IP67 T 109 °C (228.2 °F) X
The Ex-significant identification is on the enclosed adhesive label
Appropriate type NCB5-18GM…-N0…
CSA approval cCSAus Listed, General Purpose
Ambient temperature -25 … 100 °C (-13 … 212 °F)
Hysteresis 1 … 15 typ. 5 %
CE marking [*PD-Z02585A*]
Output type NAMUR
Maximum permissible ambient temperature
Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EC-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained.
ATEX marking II 1G Ex ia IIC T6andhellip;T1 Ga The Ex-related marking can also be printed on the enclosed label.
Assured operating distance 0 … 4.05 mm
Switching function Normally closed (NC)
Effective internal inductance max. 100 andmicro;H ; a cable length of 10 m is considered.
ATEX marking II 1G Ex ia IIC T6andhellip;T1 Ga
The Ex-significant identification is on the enclosed adhesive label
Output type 2-wire
UL approval cULus Listed, General Purpose
Standards EN 60079-0:2012+A11:2013, EN 60079-31:2014
Protection by enclosure “”tc”” Some of the information in this instruction manual is more specific than the information provided in the datasheet.
Standards EN 50281-1-1
Protection via housing
Use is restricted to the following stated conditions
Maximum permissible ambient temperature Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate.
Standard conformity EN 60079-15:2005 Ignition protection category “”n””
Use is restricted to the following stated conditions
Degree of protection IP67
Mission Time (TM) 20 a
Installation flush
Reduction factor rAl 0.35
Certificate PF 13 CERT 2895 X
CE marking [*PD-Z02585A*]
Effective internal capacitance max. 95 nF ; a cable length of 10 m is considered.
Effective internal capacitance max. 95 nF ; a cable length of 10 m is considered.
Effective internal capacitance Ci max. 95 nF ; a cable length of 10 m is considered.
Reduction factor rCu 0.3
Appropriate type NCB5-18GM…-N0…
Effective internal inductance max. 100 andmicro;H ; A cable length of 10 m is considered.
Use in the hazardous area see instruction manuals
CE marking [*PD-Z02585A*]
Switching frequency 0 … 400 Hz
Connection type cable PVC , 15 m
Short-circuit protection yes
Standards EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection category “”ic”” Use is restricted to the following stated conditions
General The corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet.
CE marking [*PD-Z02585A*]
Storage temperature -40 … 100 °C (-40 … 212 °F)
Actual operating distance 4.5 … 5.5 mm typ. 5 mm
Effective internal inductance max. 100 andmicro;H ; a cable length of 10 m is considered.
Diagnostic Coverage (DC) 0 %
Core cross-section 0.75 mm2
Standards EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection “”Intrinsic safety””
Use is restricted to the following stated conditions
Housing material Stainless steel 1.4305 / AISI 303
CCC approval CCC approval / marking not required for products rated 36 V
Standards EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection “”Intrinsic safety””
Use is restricted to the following stated conditions
Effective internal capacitance max. 95 nF ; a cable length of 10 m is considered.
CE marking [*PD-Z02585A*]
Reviews
Leave feedback on the goods

Currently, the goods have no revocation.
Your feedback will be the first to
Share your thoughts, your opinion about the product.

Leave feedback

Thank you for your feedback. In order to leave your feedback, simply fill out the form below.

Thank you for your feedback. In order to leave your feedback, simply fill out the form below. “Pepperl+Fuchs NCB5-18GM40-N0-15M”

Your email address will not be published. Required fields are marked *

Other products categories