Out of stock
The inductive sensor is designed for direct mounting on standard actuators, featuring a fixed setting for reliable operation. With screw terminals and LED indicators for both sensor and solenoid valve status, this sensor offers enhanced usability in industrial applications.
Pepperl+Fuchs inductive proximity sensors are robust devices utilized for non-contact detection of metallic objects. These sensors are particularly effective in automated processes where precision and reliability are paramount. Common applications include position sensing in machinery, object detection on conveyor systems, and safety interlocks in industrial environments.
This product family is characterized by its durability, compliance with international safety standards, and ability to function in potentially hazardous environments, as evidenced by its EC-Type Examination Certificate. The sensors are designed for ease of installation with direct mounting options and offer features such as fixed settings and disconnectable valve LEDs to facilitate system integration and maintenance.
| Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 20 V , Ii = 25 mA , Pi = 34 mW , T6 : 70 °C (158 °F) T5 : 85 °C (185 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 20 V , Ii = 25 mA , Pi = 64 mW , T6 : 70 °C (158 °F) T5 : 85 °C (185 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 20 V , Ii = 52 mA , Pi = 169 mW , T6 : 65 °C (149 °F) T5 : 80 °C (176 °F) T4 : 90 °C (194 °F) T3 : 90 °C (194 °F) T2 : 90 °C (194 °F) T1 : 90 °C (194 °F) |
| Nominal voltage | 8 V |
| Switching frequency | 0 … 3 kHz |
| Type of protection | intrinsic safety |
| Current | max. 240 mA |
| Equipment protection level | Ga , Gb , Gc (ic) , Mb |
| Reduction factor rBrass | 0.6 |
| Note | LED switch-off |
| Degree of protection | IP67 |
| Core cross-section (valve side) | like core cross section (system side) |
| Maximum values of the valve circuit | The value applies to each valve circuit. A cable length of 10 m is considered. |
| Short-circuit protection | no |
| Time delay before availability | 1.1 ms |
| Type of protection | intrinsic safety |
| Effective internal capacitance | max. 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
| Voltage | max. 32 V DC |
| Sensing face | PBT |
| Rated operating distance | 3 mm |
| Reverse polarity protection | reverse polarity protected |
| Tightening torque, housing screws | 1 Nm |
| Tightening torque, cable gland | M20 x 1.5 ; max. 7 Nm |
| Reduction factor rAl | 0.5 |
| Reverse polarity protection | yes, with reversed output LED is out of function, therfore more power for solenoid valve |
| Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 15 V , Ii = 25 mA , Pi = 34 mW : 100 °C (212 °F) at Ui = 15 V , Ii = 25 mA , Pi = 64 mW : 100 °C (212 °F) at Ui = 15 V , Ii = 52 mA , Pi = 169 mW : 90 °C (194 °F) |
| CE marking | [*PD-Z02585A*] |
| CE marking | [*PD-Z02585A*] |
| Switching state indicator | LED, yellow |
| CE marking | [*PD-Z02585A*] |
| Core cross-section (system side) | rigid: 0.14 … 2.5 mm2 flexible: 0.14 … 1.5 mm2 flexible with core-end sleeve: 0.25 … 1.5 mm2 |
| Safety Integrity Level (SIL) | SIL 2 |
| Effective internal inductance | max. 100 andmicro;H The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
| Hysteresis | typ. 5 % |
| MTTFd | 1470 a |
| Reduction factor r304 | 1 |
| Effective internal inductance | max. 100 andmicro;H The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
| Reduction factor rCu | 0.4 |
| Short-circuit protection | yes |
| Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. |
| Maximum values of the valve circuit | The value applies to each valve circuit. A cable length of 10 m is considered. |
| Output type | NAMUR |
| CE marking | [*PD-Z02585A*] |
| Effective internal capacitance | max. 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
| Installation | flush mountable |
| Actuating element | Stainless steel 1.4305 / AISI 303 8.5 mm x 8.5 mm x 0.5 mm |
| Effective internal inductance | max. 100 andmicro;H The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
| CCC approval | CCC approval / marking not required for products rated 36 V |
| EAC conformity | TR CU 012/2011 |
| Connection (valve side) | like connection (system side) |
| Type of protection | intrinsic safety |
| Connection (system side) | Screw terminals, tightening torque min. 0.5 Nm Stripped length 7 mm |
| Type of protection | intrinsic safety |
| Ambient temperature | -25 … 100 °C (-13 … 212 °F) |
| Output type | 2-wire |
| Reduction factor rSt37 | 1.3 |
| Effective internal capacitance | max. 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
| Assured operating distance | 0 … 2.4 mm |
| Effective internal capacitance | max. 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
| Maximum values of the valve circuit | The value applies to each valve circuit. A cable length of 10 m is considered. |
| Storage temperature | -40 … 100 °C (-40 … 212 °F) |
| Maximum values of the valve circuit | The value applies to each valve circuit. A cable length of 10 m is considered. |
| Diagnostic Coverage (DC) | 0 % |
| Mission Time (TM) | 20 a |
| Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 15 V , Ii = 25 mA , Pi = 34 mW , T6 : 70 °C (158 °F) T5 : 85 °C (185 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 15 V , Ii = 25 mA , Pi = 64 mW , T6 : 70 °C (158 °F) T5 : 85 °C (185 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 15 V , Ii = 52 mA , Pi = 169 mW , T6 : 65 °C (149 °F) T5 : 80 °C (176 °F) T4 : 90 °C (194 °F) T3 : 90 °C (194 °F) T2 : 90 °C (194 °F) T1 : 90 °C (194 °F) |
| Valve status indicator | LED, yellow |
| Housing material | PBT |
| Actual operating distance | 2.7 … 3.3 mm typ. |
| Switching function | 2 x normally closed (NC) |
| Effective internal inductance | max. 100 andmicro;H The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
| Use in the hazardous area | see instruction manuals |
Currently, the goods have no revocation.
Your feedback will be the first to
Share your thoughts, your opinion about the product.
Thank you for your feedback. In order to leave your feedback, simply fill out the form below.