Out of stock
The inductive sensor is designed for direct mounting on standard actuators, providing a fixed setting for reliable performance. It features an EC-Type Examination Certificate TV99 ATEX 1479X and is suitable for use up to SIL 2 in accordance with IEC 61508.
Inductive proximity sensors are essential components in automated systems, utilized for non-contact detection of metallic objects. These sensors operate on the principle of electromagnetic induction and are widely employed in industrial applications such as automation, packaging, and material handling. By detecting changes in the electric field generated by the presence of metal, they offer high levels of reliability and precision.
With features such as integrated LEDs for monitoring the switching state of the sensor and solenoid valve, these sensors facilitate easy diagnostics and enhance operational efficiency. The ability to disconnect valve LEDs provides flexibility in system configurations. Their compliance with ATEX directives makes them suitable for use in hazardous environments, ensuring safe operation even in challenging industrial settings.
| Effective internal capacitance | max. 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
| Reduction factor rCu | 0.4 |
| Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. |
| CE marking | [*PD-Z02585A*] |
| Effective internal capacitance | max. 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
| Core cross-section (valve side) | 1.5/2.5 mm2 flexible/rigid |
| Safety Integrity Level (SIL) | SIL 2 |
| Reverse polarity protection | yes, with reversed output LED is out of function, therfore more power for solenoid valve |
| Maximum values of the valve circuit | The value applies to each valve circuit. A cable length of 10 m is considered. |
| Reduction factor rAl | 0.5 |
| CE marking | [*PD-Z02586A*] |
| Short-circuit protection | yes |
| Tightening torque, housing screws | 1 Nm |
| Output type | 2-wire |
| Short-circuit protection | no |
| Rated operating distance | 3 mm |
| EAC conformity | TR CU 012/2011 |
| Maximum values of the valve circuit | The value applies to each valve circuit. A cable length of 10 m is considered. |
| Maximum values of the valve circuit | The value applies to each valve circuit. A cable length of 10 m is considered. |
| Type of protection | intrinsic safety |
| Tightening torque, cable gland | M20 x 1.5 ; max. 7 Nm M12 x 1.5 ; max. 1.5 Nm |
| Effective internal capacitance | max. 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
| Switching function | 2 x normally closed (NC) |
| Reduction factor rSt37 | 1.3 |
| Maximum values of the valve circuit | The value applies to each valve circuit. A cable length of 10 m is considered. |
| Degree of protection | IP67 |
| Effective internal inductance | max. 100 µH The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
| Connection (system side) | Cage tension spring terminals |
| Storage temperature | -40 … 100 °C (-40 … 212 °F) |
| Housing material | PBT |
| MTTFd | 1470 a |
| Reverse polarity protection | reverse polarity protected |
| Type of protection | intrinsic safety |
| Switching frequency | 0 … 3 kHz |
| Reduction factor rBrass | 0.6 |
| Type of protection | intrinsic safety |
| Equipment protection level | Ga , Gb , Gc (ic) , Mb |
| Nominal voltage | 8.2 V (Ri approx. 1 kΩ) |
| Ambient temperature | -25 … 100 °C (-13 … 212 °F) |
| Current | max. 240 mA |
| Reduction factor r304 | 1 |
| Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 15 V , Ii = 25 mA , Pi = 34 mW , T6 : 70 °C (158 °F) T5 : 85 °C (185 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 15 V , Ii = 25 mA , Pi = 64 mW , T6 : 70 °C (158 °F) T5 : 85 °C (185 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 15 V , Ii = 52 mA , Pi = 169 mW , T6 : 65 °C (149 °F) T5 : 80 °C (176 °F) T4 : 90 °C (194 °F) T3 : 90 °C (194 °F) T2 : 90 °C (194 °F) T1 : 90 °C (194 °F) |
| Assured operating distance | 0 … 2.4 mm |
| Time delay before availability | ≤ 1.1 ms |
| Voltage | max. 32 V DC |
| Core cross-section (system side) | 1.5/2.5 mm2 flexible/rigid |
| Actual operating distance | 2.7 … 3.3 mm typ. |
| Use in the hazardous area | see instruction manuals |
| CE marking | [*PD-Z02585A*] |
| UL approval | cULus Listed, General Purpose |
| Effective internal inductance | max. 100 µH The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
| Mission Time (TM) | 20 a |
| Valve status indicator | LED, yellow |
| Installation | flush mountable |
| Effective internal inductance | max. 100 µH The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
| CSA approval | cCSAus Listed, General Purpose |
| Switching state indicator | LED, yellow |
| Type of protection | intrinsic safety |
| Note | LED switch-off |
| Sensing face | PBT |
| Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 20 V , Ii = 25 mA , Pi = 34 mW , T6 : 70 °C (158 °F) T5 : 85 °C (185 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 20 V , Ii = 25 mA , Pi = 64 mW , T6 : 70 °C (158 °F) T5 : 85 °C (185 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 20 V , Ii = 52 mA , Pi = 169 mW , T6 : 65 °C (149 °F) T5 : 80 °C (176 °F) T4 : 90 °C (194 °F) T3 : 90 °C (194 °F) T2 : 90 °C (194 °F) T1 : 90 °C (194 °F) |
| Actuating element | Stainless steel 1.4305 / AISI 303 8.5 mm x 8.5 mm x 0.5 mm |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
| Connection (valve side) | Cage tension spring terminals |
| Output type | NAMUR |
| Scope of delivery | Cable gland , Polyamide (PA) clamping range: 6 … 7,5 mm/ 7,5 … 12 mm M20 x 1.5 thread thread length 10 mm seal: Chloropren |
| Effective internal capacitance | max. 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
| CE marking | [*PD-Z02585A*] |
| Hysteresis | typ. 5 % |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
| Effective internal inductance | max. 100 µH The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
| Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 15 V , Ii = 25 mA , Pi = 34 mW : 100 °C (212 °F) at Ui = 15 V , Ii = 25 mA , Pi = 64 mW : 100 °C (212 °F) at Ui = 15 V , Ii = 52 mA , Pi = 169 mW : 90 °C (194 °F) |
| Diagnostic Coverage (DC) | 0 % |
Currently, the goods have no revocation.
Your feedback will be the first to
Share your thoughts, your opinion about the product.
Thank you for your feedback. In order to leave your feedback, simply fill out the form below.