Out of stock
The Optical reader – safePXV is designed for safe, non-contact positioning on Data Matrix code tape, providing high reliability in automation applications. With SIL 3 certification and Category 4 PL e compliance, this device ensures safety in critical operations.
The Optical reader – safePXV represents a robust solution for precise positioning in industrial environments. It features a PROFINET interface along with a PROFIsafe interface, which allows for seamless integration into automation systems. This product is particularly suited for applications requiring safety assurance, thanks to its compliance with stringent safety standards such as SIL 3 (EN 61508) and Category 4 PL e (EN ISO 13849).
With a traverse distance capability of up to 100 km, the safePXV optical reader is engineered for long-range applications, making it ideal for production lines and logistics systems. Its mechanically rugged design eliminates wearing parts, ensuring a long operating life and maintenance-free performance. As a result, the safePXV optical reader is an essential component for enhancing operational efficiency and safety in modern automated environments.
| CE conformity | CE |
| Storage temperature | -40 … 85 °C (-40 … 185 °F) |
| Housing width | 70 mm |
| Operating voltage | 20 … 30 V DC , PELV |
| Connection type | 8-pin, M12x1 connector, standard 4-pin, M12x1 socket, D-coded (LAN) 4-pin, M12x1 socket, D-coded (LAN) |
| Power consumption | 6 W |
| Safety Integrity Level (SIL) | SIL 3 |
| Relative humidity | 90 % , noncondensing |
| MTTFd | 104.74 a |
| PFH | 1.09 E-8 typ. |
| Mass | approx. 200 g |
| Protocol | PROFINET IO Real-Time (RT) Conformance class B |
| Housing depth | 50 mm |
| Depth of focus | ± 30 mm |
| Fieldbus standard | PROFIsafe in accordance with IEC 61784-3-3; profile 2.4 |
| Functional safety | EN ISO 13849-1:2015 ; EN 61508:2010 part 1-7 ; EN 62061:2005 + AC:2010 + A1:2013 + A2:2015 |
| MTTF | 41.66 a |
| Measuring range | max. 100000 m |
| Ambient light limit | 30000 Lux |
| Mission Time (TM) | 20 a |
| No-load supply current | max. 300 mA |
| TV approval | TV Rheinland 01/205/5669.00/18 |
| Passage speed | 8 m/s |
| Shock resistance | EN 60068-2-27:2009 |
| Field of view | typ. 120 mm x 80 mm |
| Photobiological safety | risk group 2 according IEC 62471 |
| Degree of protection | IP67 |
| Housing height | 70 mm |
| Reaction time | 165 ms |
| Altitude | max. 2000 m above MSL |
| Transfer rate | 100 MBit/s |
| Light type | Integrated LED lightning (red/blue) |
| Operating temperature | 0 … 45 °C (32 … 113 °F) , -20 … 45 °C (-4 … 113 °F) (noncondensing; prevent icing on the lens!) |
| Emitted interference | EN 61000-6-4:2007+A1:2011 |
| CCC approval | CCC approval / marking not required for products rated 36 V |
| Interface type | 100 BASE-TX |
| Category | Cat. 4 |
| Read distance | 100 mm |
| LED indication | 7 LEDs (communication, status messages) |
| Performance level (PL) | PL e |
| Vibration resistance | EN 60068-2-6:2008 |
Currently, the goods have no revocation.
Your feedback will be the first to
Share your thoughts, your opinion about the product.
Thank you for your feedback. In order to leave your feedback, simply fill out the form below.