Out of stock
The Inductive slot sensor is part of the Comfort series, designed for reliable detection of metallic objects without physical contact. This sensor is ideal for various automation applications, ensuring precise and consistent operation.
The Inductive slot sensor utilizes advanced inductive proximity sensing technology, allowing for non-contact detection of metallic objects. These sensors are widely used in automation and industrial applications due to their robustness and reliability. Their design enables easy integration into existing systems, facilitating seamless operation across various environments.
Common applications for inductive proximity sensors include position detection, object counting, and end-of-travel sensing in automation equipment. They are particularly effective in environments where traditional mechanical switches may fail due to wear or environmental conditions. The Comfort series sensors are engineered to provide high performance in challenging conditions, ensuring longevity and minimal maintenance.
Switching functionNormally closed (NC)
| Housing material | PBT |
| Type of protection | intrinsic safety |
| Use in the hazardous area | see instruction manuals |
| CSA approval | cCSAus Listed, General Purpose |
| CE marking | [*PD-Z02585A*] |
| Effective internal capacitance | max. 150 nF A cable length of 10 m is considered. |
| Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 20 V , Ii = 25 mA , Pi = 34 mW , T6 : 66 °C (150.8 °F) T5 : 81 °C (177.8 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 20 V , Ii = 25 mA , Pi = 64 mW , T6 : 66 °C (150.8 °F) T5 : 81 °C (177.8 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 20 V , Ii = 52 mA , Pi = 169 mW , T6 : 45 °C (113 °F) T5 : 60 °C (140 °F) T4 : 89 °C (192.2 °F) T3 : 89 °C (192.2 °F) T2 : 89 °C (192.2 °F) T1 : 89 °C (192.2 °F) at Ui = 20 V , Ii = 76 mA , Pi = 242 mW , T6 : 30 °C (86 °F) T5 : 45 °C (113 °F) T4 : 74 °C (165.2 °F) T3 : 74 °C (165.2 °F) T2 : 74 °C (165.2 °F) T1 : 74 °C (165.2 °F) |
| Effective internal inductance | max. 150 µH A cable length of 10 m is considered. |
| Depth of immersion (lateral) | 5 … 7 typ. 6 mm |
| Switching frequency | 0 … 3000 Hz |
| Hysteresis | 0 … 0.6 mm |
| Switching state indicator | LED, yellow |
| Output type | 2-wire |
| Nominal voltage | 8 V |
| Type of protection | intrinsic safety |
| Effective internal capacitance | max. 150 nF A cable length of 10 m is considered. |
| Effective internal inductance | max. 150 µH A cable length of 10 m is considered. |
| Equipment protection level | Ga , Gb , Gc (ic) , Da , Mb |
| Type of protection | intrinsic safety |
| Operating voltage | 5 … 25 V |
| Effective internal inductance | max. 150 µH A cable length of 10 m is considered. |
| CE marking | [*PD-Z02586A*] |
| Effective internal capacitance | max. 150 nF A cable length of 10 m is considered. |
| Degree of protection | IP67 |
| Slot width | 3.5 mm |
| Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. |
| Output type | NAMUR |
| Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW : 89 °C (192.2 °F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW : 74 °C (165.2 °F) |
| Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW : 89 °C (192.2 °F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW : 74 °C (165.2 °F) |
| Effective internal capacitance | max. 150 nF A cable length of 10 m is considered. |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
| UL approval | cULus Listed, General Purpose |
| CE marking | [*PD-Z02585A*] |
| Effective internal capacitance | max. 150 nF A cable length of 10 m is considered. |
| Type of protection | intrinsic safety |
| Core cross-section | 0.14 mm2 |
| Effective internal inductance | max. 150 µH A cable length of 10 m is considered. |
| CE marking | [*PD-Z02585A*] |
| Effective internal inductance | max. 150 µH A cable length of 10 m is considered. |
| Type of protection | intrinsic safety |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
| Ambient temperature | -25 … 100 °C (-13 … 212 °F) |
| Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW , T6 : 73 °C (163.4 °F) T5 : 88 °C (190.4 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW , T6 : 66 °C (150.8 °F) T5 : 81 °C (177.8 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW , T6 : 45 °C (113 °F) T5 : 60 °C (140 °F) T4 : 89 °C (192.2 °F) T3 : 89 °C (192.2 °F) T2 : 89 °C (192.2 °F) T1 : 89 °C (192.2 °F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW , T6 : 30 °C (86 °F) T5 : 45 °C (113 °F) T4 : 74 °C (165.2 °F) T3 : 74 °C (165.2 °F) T2 : 74 °C (165.2 °F) T1 : 74 °C (165.2 °F) |
| Connection type | cable PVC , 6 m |
| EAC conformity | TR CU 012/2011 |
Currently, the goods have no revocation.
Your feedback will be the first to
Share your thoughts, your opinion about the product.
Thank you for your feedback. In order to leave your feedback, simply fill out the form below.