Out of stock
The AS-Interface EMERGENCY STOP button is a critical safety component designed for industrial applications. It features a 2-channel configuration with compelled connections and is overload-protected in compliance with IEC 60947-5-5.
The AS-Interface EMERGENCY STOP button is engineered for safety applications in industrial environments, ensuring reliable emergency stop functionality. This device is particularly suited for use in automated systems where safety and compliance with industry standards are paramount. The button’s biased actuator allows for self-monitoring, providing an additional layer of safety by ensuring that the system can detect any faults or malfunctions.
Featuring TV-approval for system components, this emergency stop button is designed to meet rigorous safety standards, making it an ideal choice for various industrial settings, including manufacturing, material handling, and process automation. The unlocking mechanism, which can be activated by turning or pulling, ensures that operators can quickly and effectively reset the system after an emergency stop, enhancing overall operational efficiency.
| ID code | B |
| MTTFd | 200 a |
| Functional safety | EN 62061:2005 EN 61508 Parts 1-7:2010 NFPA 79:2007 EN 60204-1:2006 |
| Installation | Installation in 22 mm hole |
| ID1 code | F |
| Relative humidity | 40 … 85 % , noncondensing |
| Connection | Crimp terminal sockets (JST) 1.5 m Connecting cable with crimp on 2 flexible leads supplied with delivery |
| AS-Interface specification | V2.1 |
| Mass | 105 g |
| Ambient temperature | -25 … 55 °C (-13 … 131 °F) (no freezing) |
| Degree of protection | EN 60529:2000 |
| Operating force | Push: 32 N Pull: 21 N Turn: 0.27 Nm Minimum for positive opening operation: 60 Nm |
| Rated operating voltage | 26.5 … 31.6 V from AS-Interface |
| Life span | > 250,000 switching operations |
| AS-Interface | EN 62026-2:2013 |
| Number/Type | 2 NC Safety function by positive opening in accordance with IEC/EN 60947-5-1 Reset by pulling |
| Insulation resistance | min. 100 MandOmega; |
| Data bits (function via AS-Interface) | |
| Required master specification | V2.0 |
| Protection class | III |
| ID2 code | E |
| Parameter bits (programmable via AS-i) | function |
| B10d | 1 E+5 |
| Storage temperature | -40 … 70 °C (-40 … 158 °F) |
| Operating distance | for positive opening operation: min. 4 mm maximal: 4.5 mm |
| Degree of protection | IP65 |
| Slave type | Safety-Slave |
| IO code | 0 |
| Electrical safety | EN 60947-5-5:1997+A1:2005 |
| Rated operating current | 25 mA |
| UL File Number | E198304 |
| Profile | S-0.B.E |
| Supply | from AS-Interface |
| Electromagnetic compatibility | EN 62026-2:2013 |