Out of stock
The stand-alone connecting module is designed for integrating 3-wire sensors and DC roller motors in industrial applications. This module facilitates efficient communication and control in automated systems, ensuring reliable operation and performance.
The stand-alone connecting module serves as a vital component in industrial automation, enabling seamless connectivity between sensors and DC roller motors. This module is particularly suited for applications where precise control of motor speed and operation is required, such as in conveyor systems and automated machinery.
Equipped with inputs for 3-wire sensors and outputs specifically for DC roller motors, the module supports robust communication and control functionalities. The integration of M8 connectors simplifies the installation and ensures secure connections, enhancing the overall reliability of the system. Additionally, the module features a rotary switch that allows for easy configuration of operating modes, motor speed, and start/stop ramps, facilitating tailored performance for specific operational requirements.
Furthermore, the module employs insulation piercing technology with gold-plated contact pins to ensure a stable 24 VDC power supply. A comprehensive function indicator provides real-time feedback on power supply status, input and output conditions, as well as zone coupling, making it an efficient choice for complex industrial environments.
| Altitude | ≤ 2000 m above MSL |
| Connection | PWR: insulation piercing technology Black flat cable Inputs/outputs: M8 round plug connector in accordance with EN 61076-2-104 Inputs: LF004-GS1-A (4-pin, bushing contacts, screw lock, A-coded) Matching connector: LM004-Gx1-A or similar Outputs: NF005-SS1-B (5-pin, bushing contacts, snap lock, B-coded) Matching connector: NM005-Sx1-B or similar Zone coupling: M12 round plug connector in accordance with EN 61076-2-101 X1: M12, 4-pin, bushing contacts, screw-locking, A-coded Female connector: M12, 4-pin, connector contacts, screw-locking, A-coded X2: M12, 4-pin, connector contacts, screw-locking, A-coded Female connector: M12, 4-pin, bushing contacts, screw-locking, A-coded |
| Switching point | in accordance with DIN EN 61131-2 (type 1) 0 (undamped): ≤ 0.5 mA 1 (damped): ≥ 2 mA |
| Interface type | Interface for coupling zones with one input and one output for control signals X1 |
| Velocity signal | 1.4 … 13 V at no-load Ri = 5.6 kΩ, RLOAD ≥ 35 kΩ Control using rotary switch S1 |
| LED XOUT | Zone coupling output active; 2 yellow LEDs |
| Switching point | according to DIN EN 61131-2 0 (undamped) ≤ 0.5 mA 1 (damped) ≥ 2.0 mA |
| Supply | via UPWR |
| Input | EN 61131-2:2007 |
| Mass | 310 g |
| Noise immunity | EN 61000-6-2:2005 , EN 61326-1:2006 |
| Degree of protection | EN 60529:2000 |
| Surge protection | UPWR: overvoltage category II, securely isolated power supply (PELV) |
| Pollution degree | 2 |
| Physical | 4-pin M12 socket Electronic output: PNP, overload and short-circuit proof (X1OUT) Input: PNP, galvanically isolated, potential-free (X1IN) |
| Cable length | 1 m (inputs/outputs) , 1.5 m (zone coupling), max. 30 m |
| Relative humidity | 85 % non-condensing |
| Voltage | Input: max. 30 V DC Output (via UPWR): ≥ (UPWR – 2 V) |
| Overload protection | fuse , I2t = 53.7 A2s |
| Vibration resistance | 0.75 mm 10 … 57 Hz , 5 g 57 … 150 Hz, 20 cycles |
| Number/Type | 2 outputs for DC roller motors (MOT1, MOT2) |
| Current | 2 A , max. 5 A (<2 s) per motor |
| Mounting | 2 clips with ∅ 8 mm drill hole |
| Number/Type | 2 Inputs for 3-wire sensors (PNP), DC |
| Interface type | Interface for coupling zones with one input and one output for control signals X2 |
| LED MOT | Motor active; 2 yellow LEDs |
| Climatic conditions | For indoor use only |
| Compatible roller motors | Interroll EC310, Interroll EC5000, Itoh Denki PM500XK, Rulmeca BL3 |
| Physical | M12 connector, 4-pin Electronic output: PNP, overload and short-circuit proof (X2OUT) Input: PNP, galvanically isolated, potential-free (X2IN) |
| Input filter | 10 ms |
| Rated operating current | ≤ 30 mA (Closed-circuit current) max. 10 A (<2 s) |
| Emitted interference | EN 61000-6-4:2007 |
| LED ERR | Motor fault; 2 yellow LEDs yellow: motor error flashing yellow: motor protection unit defective |
| Motor fault | NPN digital input, U0 = 14 V, Ri = 34 kΩ 0 (no error) ≥ 125 µA 1 (error) ≤ 25 µA |
| Rotation direction signal | low: high impedance high; ≥ (UPWR – 1.0 V) in no-load operation Ri = 5.6 kΩ, RLOAD ≥ 5 kΩ Control using rotary switch S2 |
| LED PWR | Supply voltage UPWR; green LED |
| Rated operating voltage | 18 V … 30 V DC PELV (via UPWR) |
| Ambient temperature | -30 … 60 °C (-22 … 140 °F) |
| LED IN | switching state (input); 2 LED yellow |
| Storage temperature | -30 … 85 °C (-22 … 185 °F) |
| Switching point | in accordance with DIN EN 61131-2 (type 1) 0 (undamped): ≤ 0.5 mA 1 (damped): ≥ 2 mA |
| Supply | via UPWR |
| Load current | Input: ≤ 8 mA (internally limited) Output: 10 mA |
| Load current | Input: ≤ 8 mA (internally limited) Output: 10 mA |
| Note | The flat cable routing is designed for 100 actuation cycles |
| UL File Number | E223772 “”For use in NFPA 79 Applications only”” |
| Voltage | Input: max. 30 V DC Output (via UPWR): ≥ (UPWR – 2 V) |
| Degree of protection | IP65 in accordance with EN 60529 (not certified by UL) |
| LED XIN | Zone coupling input active; 2 yellow LEDs |
| Shock and impact resistance | 30 g, 11 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions, 1000 shocks |
| Current loading capacity | 500 mA , overload and short-circuit protected |
| Input current | ≤ 8 mA (limited internally) |
| Switch | S1: motor speed; rotary switch, 10 positions S2: direction of rotation and start/stop ramp; rotary switch, 10 positions S3: operating mode, rotary switch, 10 positions |
Currently, the goods have no revocation.
Your feedback will be the first to
Share your thoughts, your opinion about the product.
Thank you for your feedback. In order to leave your feedback, simply fill out the form below.