Pepperl+Fuchs VBA-4E4A-G20-ZEJ/M3L-P9

AS-Interface I/O module
SKU: VBA-4E4A-G20-ZEJ/M3L-P9
0.00

Out of stock

One click request

The AS-Interface I/O module serves as a versatile A/B slave capable of addressing up to 62 slaves, making it ideal for complex industrial applications. It features both inputs for 3-wire sensors and outputs for DC roller motors, facilitating streamlined integration into automated systems.

All description
Manufacturer: Pepperl+Fuchs
Description:

The AS-Interface I/O module is designed to enhance communication and control within industrial automation systems. By functioning as an A/B slave, it allows for the effective connection of multiple sensors and actuators, supporting a broad range of applications from manufacturing to material handling. This module is particularly beneficial in environments where space and wiring complexity are critical considerations.

Equipped with inputs for 3-wire sensors and outputs for DC roller motors, the module simplifies the integration of these devices through the use of robust M8 connectors. Additionally, it features configurable start/stop ramps for motor control, communication monitoring for system integrity, and a display indicating the status of the bus, external auxiliary voltage, and in- and outputs. The power supply for the outputs comes from an external source, while the inputs are powered via the AS-Interface, ensuring reliable operation in diverse industrial settings.

Rotation direction signal PNP digital output
low: high impedance
high; (VAUX – 2.5 V) in no-load operation
ID2 code 7
Altitude 2000 m above MSL
Supply from AS-Interface
Velocity signal 0 … 10 V DC
Control via parameter P1:0
Number/Type 2 outputs for DC roller motors (MOT1, MOT2)
Ambient temperature -25 … 70 °C (-13 … 158 °F)
Data bits (function via AS-Interface) input output
Connection AS-Interface, AUX: Insulation piercing technology
Yellow flat cable/black flat cable
Inputs/outputs: M8 round plug connector in accordance with EN 61076-2-104
Inputs: LF004-GS1-A (4-pin, bushing contacts, screw lock, A-coded)
Matching connector: LM004-Gx1-A or similar
Outputs: NF005-SS1-B (5-pin, bushing contacts, snap lock, B-coded).
Matching connector: NM005-Sx1-B or similar
Current loading capacity 100 mA , overload and short-circuit protected
LED ERR Motor fault: 2 LED yellow
Profile S-7.A.7
Climatic conditions For indoor use only
MTBF 98 a
Degree of protection EN 60529:2000
Note The flat cable routing is designed for 100 actuation cycles
LED IN switching state (input); 2 LED yellow
Mounting 2 clips with andempty; 8 mm drill hole
LED PWR AS-Interface voltage; green LED
green: voltage OK
green flashing: address 0 or sensor supply overload or speed signal overload or external auxiliary voltage UAUX missing
AS-Interface EN 62026-2:2013
Current 2 A , max. 5 A (<2 s) per motor
Number/Type 2 Inputs for 3-wire sensors (PNP), DC
Input EN 61131-2:2007
Signal delay < 1 ms (input/AS-Interface)
Fieldbus standard EN 62026-2:2013
LED FUSE Motor power supply; 2 green LEDs
IO code 7
ID1 code 7
Emitted interference EN 61000-6-4:2007
LED DIR Motor rotation direction; yellow LED
Auxiliary voltage (output) 18 … 30 VDC PELV
Storage temperature -25 … 85 °C (-13 … 185 °F)
Slave type A/B slave
Rated operating voltage 26.5 … 31.6 V from AS-Interface
Pollution degree 2
Rated operating current 25 mA (without sensors) / max. 170 mA
Motor fault NPN digital input
0 (no error) 125 andmicro;A
1 (error) 25 andmicro;A
Degree of protection IP54 according to EN 60529
LED AUX ext. auxiliary voltage UAUX; dual LED green/red
green: voltage OK
red: reverse voltage
Mass 310 g
ID code A
AS-Interface specification V3.0
Relative humidity 85 % non-condensing
LED MOT Motor active; 2 yellow LEDs
LED FAULT error display; LED red
red: communication error or address is 0
red flashing: overload of sensor supply or speed signal overload or external auxiliary voltage UAUX missing
Compatible roller motors Interroll EC310, Rulmeca BL3
Cable length 1 m
Switching point according to DIN EN 61131-2
0 (undamped) 0.5 mA
1 (damped) 2.0 mA
Noise immunity EN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013
Overload protection fuse , I2t = 53.7 A2s
UL File Number E223772 “”For use in NFPA 79 Applications only””
Vibration resistance 0.35 mm / 2 g 10 … 1000 Hz
Input filter 2 ms
Input current 6 mA (internally limited)
Required master specification V2.1
Supply from external auxiliary voltage UAUX
Shock and impact resistance 30 g, 11 ms in 6 spatial directions, 3 shocks
Reviews
Leave feedback on the goods

Currently, the goods have no revocation.
Your feedback will be the first to
Share your thoughts, your opinion about the product.

Leave feedback

Thank you for your feedback. In order to leave your feedback, simply fill out the form below.

Thank you for your feedback. In order to leave your feedback, simply fill out the form below. “Pepperl+Fuchs VBA-4E4A-G20-ZEJ/M3L-P9”

Your email address will not be published. Required fields are marked *

Other products categories