Out of stock
The AS-Interface sensor/actuator module is designed for seamless integration in industrial automation systems, providing reliable connectivity for various sensors and actuators. With features such as communication monitoring and isolated relay outputs, it ensures robust performance in demanding environments.
The AS-Interface sensor/actuator module serves as a critical component in industrial automation, facilitating communication between sensors and actuators within a control system. This module is particularly suitable for applications requiring reliable signal transmission and monitoring, making it ideal for manufacturing and process automation. Its design accommodates inputs for both 2-wire and 3-wire sensors, thereby ensuring compatibility with a wide range of devices.
Equipped with removable and color-coded terminals, the module simplifies installation and maintenance, allowing for quick connections and disconnections. The selectable sensor supply option offers flexibility, enabling users to power sensors either externally or directly from the module. Additionally, the integrated function display provides real-time feedback on bus status, internal sensor supply, inputs, and outputs, enhancing operational oversight and troubleshooting capabilities.
| LED INT | Internal input supply active; LED green |
| Input current | 8 mA (limited internally) |
| Data bits (function via AS-Interface) | |
| Auxiliary voltage (input) | 12 … 30 V DC PELV |
| Parameter bits (programmable via AS-i) | function |
| AS-Interface | EN 62026-2:2013 |
| ID2 code | 7 |
| Tightening torque of clamping screws | 0.5 Nm … 0.6 Nm |
| LED IN | switching state (input); 4 LED yellow |
| Control circuit | 8 mA per relay (from AS-Interface) |
| Input/AS-Interface | Switch position INT: None Switch position EXT: reinforced insulation, rated insulation voltage 66 V DC |
| Ambient temperature | -25 … 60 °C (-13 … 140 °F) |
| Emitted interference | EN 61000-6-4:2007 |
| Input | EN 61131-2:2004 |
| Degree of protection | IP20 |
| Switching point | according to DIN EN 61131-2 (Type 2) |
| IO code | 7 |
| Degree of protection | EN 60529:2000 |
| AS-Interface specification | V3.0 |
| Profile | S-7.A.7 |
| Mounting | DIN mounting rail |
| Noise immunity | EN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 |
| UL File Number | E106378 |
| Galvanic isolation | EN 60947-1:2007 |
| Fieldbus standard | EN 62026-2:2013 |
| MTTFd | 300 a |
| Current loading capacity | 150 mA, overload- and short-circuit protected (INT) |
| Relative humidity | 85 % , noncondensing |
| Mission Time (TM) | 20 a |
| Pollution degree | 2 |
| Usage category | DC-13 and AC-14 |
| Required master specification | V3.0 |
| Supply | from AS-Interface (switch position INT, default settings) or external UEXT (switch position EXT) |
| Rated operating current | 35 mA (no sensors)/max. 210 mA |
| Storage temperature | -25 … 85 °C (-13 … 185 °F) |
| Number/Type | 4 relay outputs, normally open |
| Number/Type | 4 inputs for 2- or 3-wire sensors (PNP), DC |
| Output/Output | basic insulation, rated insulation voltage 300 V AC |
| Rated operating voltage | 26.5 … 31.6 V from AS-Interface |
| LED OUT | Switching state (output); 4 LED yellow |
| Mass | 170 g |
| Diagnostic Coverage (DC) | 0 % |
| LED PWR | AS-Interface voltage; LED green |
| Slave type | A/B slave |
| Climatic conditions | For indoor use only |
| ID code | A |
| Altitude | 2000 m above MSL |
| Voltage | 21 … 31 V DC (INT) |
| Surge protection | O1 … O4: Over voltage category II UEXT, Ue: Over voltage category III, safe isolated power supplies (PELV) |
| Supply | none |
| Signal delay | < 2 ms (input/AS-Interface) |
| Connection | removable terminals rated connection capacity: rigid/flexible (with and without wire-end ferrules): 0.25 mm2 … 2.5 mm2 for multiple-wire connection with two wires of equal cross-section: flexible with twin wire-end ferrules: 0.5 mm2 … 1.5 mm2 |
| LED FAULT | Fault display; Red LED red: Communication fault or address is 0 red, flashing: Overload, internal input supply |
| Output/AS-Interface | safe isolation, rated insulation voltage 300 V AC |
| Switching delay | < 10 ms (AS-Interface/contact) |
| Input/Output | safe isolation, rated insulation voltage 300 V AC |
| ID1 code | 7 |
Currently, the goods have no revocation.
Your feedback will be the first to
Share your thoughts, your opinion about the product.
Thank you for your feedback. In order to leave your feedback, simply fill out the form below.