Out of stock
The AS-Interface sensor/actuator module is designed to facilitate seamless integration of sensors and actuators in industrial automation systems. It features advanced monitoring capabilities and supports both 2-wire and 3-wire sensors for versatile applications.
The AS-Interface sensor/actuator module serves as a crucial component in modern industrial automation, enabling efficient communication and control of connected devices. This module is particularly valuable in environments that require reliable sensor and actuator management, offering features like communication monitoring and lead breakage detection.
With removable, mechanically coded terminals, installation and maintenance are streamlined, allowing for quick modifications and troubleshooting. The module supports external power supply for its outputs and provides selectable power options for sensors, enhancing flexibility in system design. Additionally, the integrated function display offers real-time status indicators for bus communication, power supply, and input/output conditions, ensuring optimal performance and reliability in demanding industrial applications.
| Rated operating current | 35 mA (without sensors) / max. 190 mA |
| Mounting | DIN mounting rail |
| LED IN | switching state (input); 4 LED yellow |
| Profile | S-7.A.7 |
| Noise immunity | EN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 |
| Input | EN 61131-2:2004 |
| Tightening torque of clamping screws | 0.5 Nm … 0.6 Nm |
| LED INT | Internal input supply active; LED green |
| Ambient temperature | -25 … 60 °C (-13 … 140 °F) |
| Pollution degree | 2 |
| LED PWR | AS-Interface voltage; green LED green: voltage OK flashing green: address 0 |
| Current | 2 A per output, sum 4A (TB 40 °C) 0.5 A per output, total 2A (TB 60 °C, arranged in series without gaps) 2 A per output, total 4A (TB 60 °C, arranged in series with 5 mm gap) |
| Rated operating voltage | 26.5 … 31.6 V from AS-Interface |
| Usage category | DC-13 |
| Auxiliary voltage (output) | 20 … 30 V DC PELV |
| Supply | from external auxiliary voltage UAUX |
| Input current | 9 mA (limited internally) |
| Signal delay | < 1 ms (input/AS-Interface) |
| LED OUT | switching state (output); 4 LED yellow/red yellow: output active red: output overload or lead interruption |
| Auxiliary voltage (input) | 12 … 30 V DC PELV |
| Switching point | according to DIN EN 61131-2 (Type 2) |
| Current loading capacity | 150 mA, overload- and short-circuit protected (INT) |
| Storage temperature | -25 … 85 °C (-13 … 185 °F) |
| UL File Number | E223772 |
| Degree of protection | IP20 |
| Number/Type | 4 inputs for 2- or 3-wire sensors (PNP), DC |
| Slave type | A/B slave |
| Emitted interference | EN 61000-6-4:2007 |
| Supply | from AS-Interface (switch position INT, default settings) or external UEXT (switch position EXT) |
| Parameter bits (programmable via AS-i) | function |
| Number/Type | 4 electronic outputs, PNP, overload and short-circuit proof |
| Connection | removable terminals rated connection capacity: rigid/flexible (with and without wire-end ferrules): 0.25 mm2 … 2.5 mm2 for multiple-wire connection with two wires of equal cross-section: flexible with twin wire-end ferrules: 0.5 mm2 … 1.5 mm2 |
| Diagnostic Coverage (DC) | 0 % |
| AS-Interface | EN 62026-2:2013 |
| LED AUX | ext. auxiliary voltage UAUX; dual LED green/red green: voltage OK red: reverse voltage |
| AS-Interface specification | V3.0 |
| IO code | 7 |
| Mass | 150 g |
| Data bits (function via AS-Interface) | |
| Surge protection | UEXT, UAUX, Ue: overvoltage category II, safe isolated power supplies (PELV) |
| Voltage | (UAUX – 0.5 V) |
| Relative humidity | 85 % , noncondensing |
| Climatic conditions | For indoor use only |
| Altitude | 2000 m above MSL |
| MTTFd | 190 a |
| ID1 code | 7 |
| Degree of protection | EN 60529:2000 |
| Fieldbus standard | EN 62026-2:2013 |
| LED FAULT | Error display; red LED red: communication error, i.e. address is 0 red flashing: overload internal input supply, i.e. overload or lead interruption outputs |
| Voltage | 21 … 31 V DC (INT) |
| ID code | A |
| Protection class | III |
| Mission Time (TM) | 20 a |
| Required master specification | V3.0 |
| ID2 code | 7 |
Currently, the goods have no revocation.
Your feedback will be the first to
Share your thoughts, your opinion about the product.
Thank you for your feedback. In order to leave your feedback, simply fill out the form below.