Gateway and safety monitor in one housing
-
Connection to Ethernet Modbus TCP/IP
-
SafeLink
-
Integrated data decoupling
The AS-Interface Gateway/Safety Monitor represents a sophisticated solution within the realm of industrial automation, specifically designed for seamless integration into existing networks. This device functions as both a gateway and a safety monitor, allowing for efficient communication between AS-Interface devices and higher-level control systems through a robust Ethernet Modbus TCP/IP connection. Its dual functionality is ideal for applications requiring stringent safety protocols alongside reliable data transmission.
Commonly employed in industrial settings, this product is particularly valuable in scenarios where safety and data integrity are paramount. The integrated SafeLink technology ensures secure data transfer, while the integrated data decoupling feature protects system components from potential disruptions. Such capabilities make it an essential tool for manufacturers focused on enhancing operational efficiency while maintaining compliance with safety standards.
|
Protocol |
EtherNet/IP + MODBUS TCP/IP acc. to IEEE 802.3 supports device level ring protocol DLR |
|
Insulation voltage |
500 V |
|
Safety Integrity Level (SIL) |
SIL 3 |
|
MTTFd |
200 a |
|
Number/Type |
4 EDM/Start inputs: EDM: Inputs for the external device monitoring circuits Start: start inputs: Static switching current 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 andmu;s) |
|
AS-Interface specification |
V3.0 |
|
Interface type |
2 x RJ-45 |
|
Ambient temperature |
0 … 55 °C (32 … 131 °F) |
|
ESC button |
Mode selection traditional-graphical/cancel |
|
Duplicate address detection |
from AS-Interface slaves |
|
Storage temperature |
-25 … 85 °C (-13 … 185 °F) |
|
Safety output |
Output circuits 1 and 2: 2 potential-free contacts, max. contact load: 3 ADC-13 at 30 VDC, 3 AAC-15 at 30 VAC Output circuits 3 and 4: 2 PNP transistor outputs max. contact load: 0.5 ADC-13 at 30 VDC |
|
Button |
4 |
|
Button MODE |
Mode selection PRJ-operation/save configuration/cursor |
|
Performance level (PL) |
PL e |
|
Transfer rate |
10 MBit/s |
|
Response delay |
< 40 ms |
|
Switch-on delay |
< 10 s |
|
AS-Interface |
EN 62026-2:2013 |
|
Interface type |
Ethernet: RJ-45 Diagnostic Interface |
|
Construction type |
Low profile housing , Stainless steel |
|
LED output circuit |
Output circuit closed; 4 x green LEDs |
|
Transfer rate |
10 MBit/s / 100 MBit/s , Automatic baud rate detection |
|
OK button |
Mode selection traditional-graphical/confirmation |
|
LED PRJ MODE |
projecting mode active; LED yellow |
|
LED CONFIG ERR |
configuration error; LED red |
|
EMC monitoring |
integrated |
|
LED AUX |
ext. auxiliary voltage UAUX ; LED green |
|
Mass |
800 g |
|
Degree of protection |
IP20 |
|
Earth fault detection |
integrated |
|
B10d |
2 E+7 |
|
Rated operating voltage |
26.5 … 31.6 V from AS-Interface; Output K3 and K4 24 V DC |
|
LED U AS-i |
AS-Interface voltage; LED green |
|
Interface type |
Chip card slot |
|
UL approval |
An isolated source with a secondary open circuit voltage of 30 VDC with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed. UL mark does not provide UL certification for any functional safety rating or aspects of the device. |
|
LED AS-i ACTIVE |
AS-Interface operation normal; LED green |
|
Electromagnetic compatibility |
EN 61000-6-2:2005, EN 61000-6-4:2007 |
|
LED EDM/Start |
External device monitoring circuit inputs closed, 4x yellow LEDs |
|
Rated operating current |
300 mA from AS-Interface |
|
LED ETHERNET |
ethernet active; LED green |
|
Degree of protection |
EN 60529:2000 |
|
UL File Number |
E223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source |
|
LED PRG ENABLE |
autom. programming; LED green |
|
LED POWER |
voltage ON; LED green |
|
Display |
Illuminated graphical LC display for addressing and error messages |
|
PLC-Functionality |
activateable |
|
Diagnostics function |
Extended function via display |
|
Standards |
EN 61000-6-2:2005, EN 61000-6-4:2007 EN 61326-3-1:2008 IEC 61508:2010 and EN 62061:2005 (up to SIL3) EN 13849:2008 (PL e) |
|
Ethernet |
RJ-45 |
|
Switch SET |
Selection and setting of a slave address |