Out of stock
The AS-Interface Gateway/Safety Monitor integrates a versatile gateway and safety monitoring solution within a single housing, ensuring compliance with AS-Interface specification 3.0. It supports efficient connectivity to Ethernet Modbus TCP/IP and features an enhanced range of functions for safety monitoring.
The AS-Interface Gateway/Safety Monitor is a critical component for industrial automation, facilitating seamless communication between various devices within an AS-Interface network. This product is designed to enhance operational safety and efficiency by integrating a safety monitor with an AS-Interface gateway, allowing for a simplified architecture in complex systems.
Commonly utilized in manufacturing and process automation, this device supports up to two AS-Interface networks and features two safe output relays and two safe electronic outputs, ensuring reliable safety functionality. The unit is certified up to SIL 3 according to IEC 61508 and EN 62061, as well as up to PLe according to EN 13849, making it suitable for applications that require high safety integrity levels. Additionally, the integrated switch allows for line topology, while DLR technology enables flexible ring topology configurations.
| Performance level (PL) | PL e |
| EMC monitoring | integrated |
| LED PRG ENABLE | autom. programming; LED green |
| Mass | 800 g |
| Rated operating current | 300 mA off AS interface network 1 300 mA off AS interface network 2 370 mA in total |
| LED POWER | voltage ON; LED green |
| Protocol | EtherNet/IP + MODBUS TCP/IP acc. to IEEE 802.3 supports device level ring protocol DLR |
| Display | Illuminated graphical LC display for addressing and error messages |
| LED ETHERNET | ethernet active; LED green |
| Degree of protection | IP20 |
| Transfer rate | 19,2 kBit/s |
| Duplicate address detection | from AS-Interface slaves |
| AS-Interface | EN 62026-2:2013 |
| Interface type | RS 232, serial Diagnostic Interface |
| LED CONFIG ERR | configuration error; LED red |
| AS-Interface specification | V3.0 |
| B10d | 2 E+7 |
| Standards | EN 61000-6-2:2005, EN 61000-6-4:2007 EN 954-1:1996 (up to Kategorie 4), IEC 61508:2001 and EN 62061:2005 (up to SIL3) EN 13849:2008 (PL e) |
| Degree of protection | EN 60529:2000 |
| Storage temperature | -25 … 85 °C (-13 … 185 °F) |
| Interface type | Chip card slot |
| Transfer rate | 10 MBit/s / 100 MBit/s , Automatic baud rate detection |
| Response delay | < 40 ms |
| Insulation voltage | 500 V |
| Earth fault detection | integrated |
| Number/Type | 4 EDM/Start inputs: EDM: Inputs for the external device monitoring circuits Start: start inputs: Static switching current 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 andmu;s) |
| Construction type | Low profile housing , Stainless steel |
| Interface type | 2 x RJ-45 |
| Ethernet | RJ-45 |
| Ambient temperature | 0 … 55 °C (32 … 131 °F) |
| Switch-on delay | < 10 s |
| AS-Interface | spring terminals, removable |
| UL approval | An isolated source with a secondary open circuit voltage of 30 VDC with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed. UL mark does not provide UL certification for any functional safety rating or aspects of the device. |
| PLC-Functionality | activateable |
| LED U AS-i | AS-Interface voltage; LED green |
| UL File Number | E223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source |
| Rated operating voltage | 26.5 … 31.6 V from AS-Interface; Output K3 and K4 24 V DC |
| Button | 4 |
| Diagnostics function | Extended function via display |
| LED output circuit | Output circuit closed; 4 x green LEDs |
| MTTFd | 200 a |
| Safety output | max. contact load: Output circuits 1 and 2: 2 potential-free contacts, 3 ADC-13 at 30 VDC, 3 AAC-15 at 30 VAC Output circuits 3 and 4: 2 PNP transistor outputs 0.5 ADC-13 at 30 VDC |
| LED EDM/Start | External device monitoring circuit inputs closed, 4x yellow LEDs |
| Safety Integrity Level (SIL) | SIL 3 |
| Electromagnetic compatibility | EN 61000-6-2:2005, EN 61000-6-4:2007 |
| LED PRJ MODE | projecting mode active; LED yellow |
| LED AS-i ACTIVE | AS-Interface operation normal; LED green |
| LED AUX | ext. auxiliary voltage UAUX ; LED green |
Currently, the goods have no revocation.
Your feedback will be the first to
Share your thoughts, your opinion about the product.
Thank you for your feedback. In order to leave your feedback, simply fill out the form below.