Out of stock
The AS-Interface Gateway/Safety Monitor integrates gateway functionalities and safety monitoring in a single housing, facilitating seamless communication and safety management in industrial automation systems.
It supports connection to PROFIBUS DP and is equipped with SafeLink technology, ensuring reliable operation in safety-critical applications.
The AS-Interface Gateway/Safety Monitor serves as a crucial component in industrial automation, providing a dual functionality that combines gateway and safety monitoring capabilities within one device. This product is designed to facilitate the integration of AS-Interface networks with higher-level systems, particularly those utilizing PROFIBUS DP for effective data communication.
With certification up to SIL 3 according to IEC 61508 and EN 62061, as well as PLe according to EN 13849, this device ensures compliance with stringent safety standards, making it suitable for applications where safety is paramount. The two AS-Interface networks, along with two safe output relays and safe electronic outputs, allow for versatile configurations in various automation setups.
The integrated data decoupling feature enhances system reliability, while diagnostics capabilities via the RJ45 Ethernet port provide essential monitoring and troubleshooting tools. This combination of features makes the AS-Interface Gateway/Safety Monitor an ideal solution for applications in manufacturing, process control, and safety-critical environments.
| Construction type | Low profile housing , Stainless steel |
| Rated operating current | 300 mA off AS interface network 1 70 mA off AS interface network 2 |
| Interface type | RS-485 |
| Protocol | PROFIBUS DP V1 |
| Diagnostics function | Extended function via display |
| Switch-on delay | < 10 s |
| Electromagnetic compatibility | EN 61000-6-2:2005, EN 61000-6-4:2007 |
| LED AS-i ACTIVE | AS-Interface operation normal; LED green |
| Button | 4 |
| AS-Interface specification | V3.0 |
| LED CONFIG ERR | configuration error; LED red |
| UL File Number | E223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source |
| Earth fault detection | integrated |
| LED U AS-i | AS-Interface voltage; LED green |
| Transfer rate | 9.6 kBit/s / 12 MBit/s , Automatic baud rate detection |
| Ambient temperature | 0 … 55 °C (32 … 131 °F) |
| LED output circuit | Output circuit closed; 4 x green LEDs |
| Performance level (PL) | PL e |
| EMC monitoring | integrated |
| LED EDM/Start | External device monitoring circuit inputs closed, 4x yellow LEDs |
| Storage temperature | -25 … 85 °C (-13 … 185 °F) |
| Number/Type | 4 EDM/Start inputs: EDM: Inputs for the external device monitoring circuits Start: start inputs: Static switching current 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 andmu;s) |
| Response delay | < 40 ms |
| AS-Interface | spring terminals, removable |
| Safety output | Output circuits 1 and 2: 2 potential-free contacts, max. contact load: 3 ADC-13 at 30 VDC, 3 AAC-15 at 30 VAC Output circuits 3 and 4: 2 PNP transistor outputs max. contact load: 0.5 ADC-13 at 30 VDC |
| Degree of protection | IP20 |
| Rated operating voltage | 26.5 … 31.6 V from AS-Interface; Output K3 and K4 24 V DC |
| B10d | 2 E+7 |
| PROFIBUS | Sub-D interface |
| Degree of protection | EN 60529:2000 |
| LED AUX | ext. auxiliary voltage UAUX ; LED green |
| Standards | IEC 61508:2010 (SIL3) IEC 62061:2005 (SIL3) EN ISO 13849-1:2008 (PL e) |
| MTTFd | 200 a |
| UL approval | An isolated source with a secondary open circuit voltage of 30 VDC with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed. UL mark does not provide UL certification for any functional safety rating or aspects of the device. |
| PLC-Functionality | activateable |
| LED PRG ENABLE | autom. programming; LED green |
| Fieldbus standard | PROFIBUS according to DIN 19245 Part 3 |
| Safety Integrity Level (SIL) | SIL 3 |
| LED PROFIBUS | PROFIBUS master detected; LED green |
| LED PRJ MODE | projecting mode active; LED yellow |
| AS-Interface | EN 62026-2:2013 |
| Interface type | Ethernet: RJ-45 Diagnostic Interface |
| Insulation voltage | 500 V |
| Display | Illuminated graphical LC display for addressing and error messages |
| LED POWER | voltage ON; LED green |
| Interface type | Chip card slot |
| Mass | 800 g |
| Duplicate address detection | from AS-Interface slaves |
Currently, the goods have no revocation.
Your feedback will be the first to
Share your thoughts, your opinion about the product.
Thank you for your feedback. In order to leave your feedback, simply fill out the form below.